AD7147AACBZ-RL Analog Devices Inc, AD7147AACBZ-RL Datasheet - Page 26

no-image

AD7147AACBZ-RL

Manufacturer Part Number
AD7147AACBZ-RL
Description
CAPACITANCE TO DIGITAL CONVERTER
Manufacturer
Analog Devices Inc
Series
CapTouch™r
Type
Capacitive Sensor Controllerr
Datasheet

Specifications of AD7147AACBZ-RL

Resolution (bits)
16 b
Data Interface
Serial, SPI™
Voltage Supply Source
Single Supply
Voltage - Supply
2.6 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
25-WLCSP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sampling Rate (per Second)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
AD7147A
Table 15. Additional Information About Environmental Calibration and Adaptive Threshold Registers
Register/Bit
NEG_THRESHOLD_SENSITIVITY
NEG_PEAK_DETECT
POS_THRESHOLD_SENSITIVITY
POS_PEAK_DETECT
STAGEx_OFFSET_LOW
STAGEx_OFFSET_HIGH
STAGEx_OFFSET_HIGH_CLAMP
STAGEx_OFFSET_LOW_CLAMP
STAGEx_SF_AMBIENT
STAGEx_HIGH_THRESHOLD
STAGEx_LOW_THRESHOLD
16-BIT
CDC
Σ-Δ
16
Register
Location
Bank 2
Bank 2
Bank 2
Bank 2
Bank 2
Bank 3
Bank 3
Bank 3
Figure 38. Tracking the Minimum and Maximum Average Sensor Values
Bank 2
Bank 2
Bank 2
Used in Equation 2. This value is programmed once at startup.
Used in Equation 1. This value is programmed once at startup.
Used by internal adaptive threshold logic only.
Used by internal environmental calibration and adaptive threshold algorithms only.
Used by internal environmental calibration and adaptive threshold algorithms only.
Used in Equation 1 and Equation 2. This is the ambient sensor output when the sensor is not
Equation 1 value.
Equation 2 value.
Description
Used by internal adaptive threshold logic only.
The NEG_PEAK_DETECT is set to a percentage of the difference between the ambient
CDC value and the minimum average CDC value. If the output of the CDC approaches the
NEG_PEAK_DETECT percentage of the minimum average, the minimum average value is updated.
The POS_PEAK_DETECT is set to a percentage of the difference between the ambient
CDC value and the maximum average CDC value. If the output of the CDC approaches the
POS_PEAK_DETECT percentage of the maximum average, the maximum average value is updated.
Used in Equation 2. An initial value (based on sensor characterization) is programmed into
this register at startup. The AD7147A on-chip calibration algorithm automatically updates
this register based on the amount of sensor drift due to changing ambient conditions. Set
this register to 80% of the STAGEx_OFFSET_LOW_CLAMP value.
Used in Equation 1. An initial value (based on sensor characterization) is programmed into
this register at startup. The AD7147A on-chip calibration algorithm automatically updates
this register based on the amount of sensor drift due to changing ambient conditions. Set
this register to 80% of the STAGEx_OFFSET_HIGH_CLAMP value.
An initial value (based on sensor characterization) is programmed into this register at startup.
The value in this register prevents a user from causing the output value of a sensor to exceed
the expected nominal value.
Set this register to the maximum expected sensor response or the maximum change in CDC
output code.
An initial value (based on sensor characterization) is programmed into this register at startup.
The value in this register prevents a user from causing the output value of a sensor to exceed
the expected nominal value.
Set this register to the minimum expected sensor response or the minimum change in CDC
output code.
touched, as calculated using the slow FIFO.
DETECTION
DETECTION
MAXIMUM
MINIMUM
LEVEL
LOGIC
LEVEL
LOGIC
Rev. B | Page 26 of 68
STAGEx_HIGH_THRESHOLD
STAGEx_LOW_THRESHOLD
STAGEx_MAX_WORD0
STAGEx_MAX_WORD1
STAGEx_MAX_WORD2
STAGEx_MAX_WORD3
STAGEx_MIN_WORD0
STAGEx_MIN_WORD1
STAGEx_MIN_WORD2
STAGEx_MIN_WORD3
STAGEx_MAX_TEMP
BANK 3 REGISTERS
BANK 3 REGISTERS
BANK 3 REGISTERS
BANK 3 REGISTERS
BANK 3 REGISTERS
BANK 3 REGISTERS
STAGEx_MAX_AVG
STAGEx_MIN_TEMP
STAGEx_MIN_AVG
BANK 3 REGISTERS
BANK 3 REGISTERS

Related parts for AD7147AACBZ-RL