ADT7470ARQZ-REEL Analog Devices Inc, ADT7470ARQZ-REEL Datasheet - Page 31

IC,Motor Controller,SSOP,16PIN

ADT7470ARQZ-REEL

Manufacturer Part Number
ADT7470ARQZ-REEL
Description
IC,Motor Controller,SSOP,16PIN
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADT7470ARQZ-REEL

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Fan Speed Control, Register Bank
Sensor Type
External
Sensing Temperature
External Sensor
Output Type
I²C™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-ADT7470EBZ - BOARD EVALUATION FOR ADT7470
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7470ARQZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Table 32. Register 0x41. Interrupt Status Register 1 (Power-On Default = 0x00).
Bit Name
[0] R1T
[1] R2T
[2] R3T
[3] R4T
[4] R5T
[5] R6T
[6] R7T
[7] OOL
Table 33. Register 0x42. Interrupt Status Register 2 (Power-On Default = 0x00).
Bit Name
[0] R8T
[1] R9T
[2] R10T
[3] NORM
[4] Fan 1
[5] Fan 2
[6] Fan 3
[7] Fan 4
Read/Write
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read/Write
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Description
A 1 indicates that the Remote 1 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the Remote 2 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the Remote 3 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the Remote 4 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the Remote 5 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the Remote 6 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the Remote 7 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that an out-of-limit event has been latched in Status Register 2. This bit is a
logical OR of all status bits in Status Register 2. Software can test this bit in isolation to
determine whether any of the temperature or fan speed readings represented by Status
Register 2 are out of limit. This saves the need to read Status Register 2 every interrupt or
polling cycle.
Description
A 1 indicates that the Remote 8 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the Remote 9 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the Remote 10 temperature high or low limit has been exceeded.
This bit is cleared on a read of the status register only if the error condition has subsided.
A 1 indicates that the measured temperatures are normal (below T
be off.
A 1 indicates that Fan 1 has gone above max speed or dropped below min speed.
A 1 indicates that Fan 2 has gone above max speed or dropped below min speed.
A 1 indicates that Fan 3 has gone above max speed or dropped below min speed.
A 1 indicates that Fan 4 has gone above max speed or dropped below min speed.
Rev. C | Page 31 of 40
MIN
), and the fans should
ADT7470

Related parts for ADT7470ARQZ-REEL