Specifications of ADUM1311BRWZ-RL

Inputs - Side 1/side 2
2/1
Number Of Channels
3
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
10Mbps
Propagation Delay
50ns
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM1311BRWZ-RL
Manufacturer:
MOT
Quantity:
1 140
Part Number:
ADUM1311BRWZ-RL
Manufacturer:
ADI原装
Quantity:
20 000
ADuM1310/ADuM1311
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)
Capacitance (Input-to-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance
1
2
REGULATORY INFORMATION
The ADuM131x have been approved by the organizations listed in Table 5. See Table 10 and the Insulation Lifetime section for
recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL
Recognized Under 1577 Component
Recognition Program
Double/Reinforced Insulation, 2500 V rms
Isolation Voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL 1577, each ADuM131x is proof-tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 μA).
In accordance with DIN V VDE V 0884-10, each ADuM131x is proof-tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge detection
limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10 approval.
Side 1
Side 2
2
1
1
1
Symbol
R
C
C
θ
θ
I-O
JCI
JCO
I-O
I
CSA
Approved under CSA Component
Acceptance Notice #5A
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 800 V rms (1131 V peak)
maximum working voltage
Reinforced insulation per CSA 60950-1-03
and IEC 60950-1, 400 V rms (566 V peak)
maximum working voltage
File 205078
Symbol
L(I01)
L(I02)
CTI
Min
Rev. G | Page 10 of 24
Typ
10
2.2
4.0
33
28
12
Value
2500
7.7 min
8.1 min
0.017 min
>175
IIIa
Max
Unit
Ω
pF
pF
°C/W
°C/W
Unit
V rms
mm
mm
mm
V
Test Conditions
f = 1 MHz
Thermocouple located at center of package underside
Conditions
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
VDE
Certified according to DIN V VDE V 0884-10 (VDE
V 0884-10): 2006-12
Reinforced insulation, 560 V peak
File 2471900-4880-0001