CS5330A-KS Cirrus Logic Inc, CS5330A-KS Datasheet - Page 14

A/D Converter (A-D) IC

CS5330A-KS

Manufacturer Part Number
CS5330A-KS
Description
A/D Converter (A-D) IC
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CS5330A-KS

Input Channels Per Adc
2
Mounting Type
Surface Mount
No. Of Channels
2
Supply Voltage Min
4.75V
Operating Temperature Max
70°C
Peak Reflow Compatible (260 C)
No
Sample Rate
50kSPS
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5330A-KS
Quantity:
200
Part Number:
CS5330A-KS
Manufacturer:
CIRRUS
Quantity:
10 000
Part Number:
CS5330A-KSZ
Manufacturer:
CRYSTAL
Quantity:
14 236
14
4. PARAMETER DEFINITIONS
Resolution
Dynamic Range
Total Harmonic Distortion+Noise (THD+N)
Total Harmonic Distortion
Interchannel Phase Deviation
Interchannel Isolation
Interchannel Gain Mismatch
Gain Error
Gain Drift
Bipolar Offset Error
The total number of possible output codes is equal to 2 N, where N = the number of bits in the output word
for each channel.
The ratio of the full-scale rms value of the signal to the rms sum of all other spectral components over the
specified bandwidth. Dynamic range is a signal-to-noise measurement over the specified bandwidth made
with a -60 dBFS signal. 60 dB is then added to the resulting measurement to refer the measurement to full
scale. This technique ensures that the distortion components are below the noise level and do not effect the
measurement. This measurement technique has been accepted by the Audio Engineering Society, AES17-
1991, and the Electronic Industries Association of Japan, EIAJ CP-307.
The ratio of the rms value of the signal to the rms sum of all other spectral components over the specified
band width (typically 10 Hz to 20 kHz), including distortion components. Expressed in decibels. Measured
at -1 and -20 dBFS as suggested in AES17-1991 Annex A.
The ratio of the rms sum of all harmonics up to 20 kHz to the rms value of the signal.
The phase difference between the left and right channel sampling times.
A measure of crosstalk between the left and right channels. Measured for each channel at the converter’s
output with the input under test AC grounded and a full-scale signal applied to the other channel. Units in
decibels.
The gain difference between left and right channels. Units in decibels.
The deviation of the measured full-scale amplitude from the ideal full-scale amplitude value.
The change in gain value with temperature. Units in ppm/°C.
The deviation of the mid-scale transition (111...111 to 000...000) from the ideal. Units in LSBs.
CS5330A/31A
DS138F5

Related parts for CS5330A-KS