CS5376A-IQZ Cirrus Logic Inc, CS5376A-IQZ Datasheet - Page 55

no-image

CS5376A-IQZ

Manufacturer Part Number
CS5376A-IQZ
Description
IC,Digital Filter,QFP,64PIN,PLASTIC
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5376A-IQZ

Filter Type
Digital
Number Of Filters
4
Max-order
2nd
Voltage - Supply
3 V ~ 5 V
Mounting Type
Surface Mount
Package / Case
64-TQFP, 64-VQFP
Package
64TQFP
Operating Temperature
-40 to 85 °C
Resolution (bits)
24bit
Conversion Rate
4kSPS
Operating Temperature Range
-40°C To +85°C
No. Of Pins
64
Msl
MSL 3 - 168 Hours
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1778 - EVALUATION BOARD FOR CS5376
Frequency - Cutoff Or Center
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5376A-IQZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS5376A-IQZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS5376A-IQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
14.IIR FILTER
The infinite impulse response (IIR) filter block
consists of two cascaded stages, IIR1 and IIR2. It
creates a high-pass corner to block very low-fre-
quency and DC components of the input signal.
On-chip IIR1 and IIR2 coefficients can be selected
using a configuration command, or the coefficients
can be programmed for a custom filter response.
14.1 IIR Architecture
The architecture of the IIR filter is automatically
determined when the output filter stage is selected
in the FILTCFG register. Selecting the 1st order
IIR1 filter bypasses the 2nd order stage, while se-
lecting the 2nd order IIR2 filter bypasses the 1st or-
der stage. Selection of the 3rd order IIR3 filter
enables both the 1st and 2nd order stages.
14.2 IIR1 Filter
The 1st order IIR filter stage is a direct form filter
with three coefficients: a11, b10, and b11. Coeffi-
cients of a 1st order IIR are inherently normalized
to one, and should be scaled to 24-bit two’s com-
plement full scale, 0x7FFFFF.
DS612F4
3rd Order IIR3 implemented by
running both IIR1 and IIR2 stages
-a
1st Order IIR1
11
Z
-1
Figure 28. IIR Filter Block Diagram
b
b
10
11
The characteristic equations for the 1st order IIR
include an input value, X, an output value, Y, and
two intermediate values, W1 and W2, separated by
a delay element (z
W2 = W1
W1 = X + (-a11 * W2)
Y = (W1 * b10) + (W2 * b11)
14.3 IIR2 Filter
The 2nd order IIR filter stage is a direct form filter
with five coefficients: a21, a22, b20, b21, and b22.
Coefficients of a 2nd order IIR are inherently nor-
malized to two, and should be scaled to 24-bit
two’s complement full scale, 0x7FFFFF. Normal-
ization effectively divides the 2nd order coeffi-
cients in half relative to the input, and requires
modification of the characteristic equations.
The characteristic equations for the 2nd order IIR
include an input value, X, an output value, Y, and
three intermediate values, W3, W4, and W5, each
separated by a delay element (z
-a
-a
2nd Order IIR2
21
22
Z
Z
-1
-1
-1
b
b
b
).
20
21
22
-1
). The following