CYWUSB6935-48LTXI Cypress Semiconductor Corp, CYWUSB6935-48LTXI Datasheet - Page 21

CYWUSB6935-48LTXI

CYWUSB6935-48LTXI

Manufacturer Part Number
CYWUSB6935-48LTXI
Description
CYWUSB6935-48LTXI
Manufacturer
Cypress Semiconductor Corp
Series
WirelessUSB™r

Specifications of CYWUSB6935-48LTXI

Frequency
2.4GHz
Data Rate - Maximum
62.5kbps
Modulation Or Protocol
GFSK
Applications
General Purpose
Power - Output
0dBm
Sensitivity
-95dBm
Voltage - Supply
2.7 V ~ 3.6 V
Current - Receiving
57.7mA
Current - Transmitting
69.1mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
48-VQFN Exposed Pad, 48-HVQFN, 48-SQFN, 48-DHVQFN
Operating Temperature (min)
0C
Operating Temperature (max)
70C
Operating Temperature Classification
Commercial
Product Depth (mm)
7mm
Product Length (mm)
7mm
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Compliant
Other names
428-2985
Table 33. Clock Enable
Table 34. Synthesizer Lock Count
Table 35. Manufacturing ID
Document #: 38-16008 Rev. *E
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
31:30 Address[31:30] These bits are read back as zeroes.
Bit Name
7:0 Count Determines the length of delay in 2-µs increments for the synthesizer to lock when auto synthesizer is enabled via
Bit
7:0 Manual Clock
29:0 Address[29:0]
Bit
Enables
7
7
Address 0x3F
Addr: 0x33
Addr: 0x38
Addr: 0x3C-3F
Name
Control register (0x03, bit 1=0) and not using the PLL lock signal. The default register setting is typically sufficient.
Name
6
6
These bits are the Manufacturing ID (MID) for each IC. The contents of these bits cannot be read unless the
MID Read Enable bit (bit 5) is set in the Analog Control register (Reg 0x20). Enabling the Manufacturing ID
register (Reg 0x3C-0x3F) consumes power. The MID Read Enable bit in the Analog Control register (Reg
0x20, bit 5) should only be set when reading the contents of the Manufacturing ID register (Reg 0x3C-0x3F).
This register is read-only.
This register must be written with 0x41 after reset for correct operation
5
5
Address 0x3E
REG_CLOCK_ENABLE
REG_SYN_LOCK_CNT
Manual Clock Enables
4
4
REG_MID
Count
Description
Description
3
3
Description
Address 0x3D
2
2
8
7
6
1
1
CYWUSB6935
Address 0x3C
Default: 0x00
Default: 0x64
5
4
3
Page 21 of 34
2
0
0
1
0
[+] Feedback