KSZ8842-16MBL Micrel Inc, KSZ8842-16MBL Datasheet - Page 110

2-Port Ethernet Switch/Repeater + Generic (8, 16-bit) Bus Interface ( )

KSZ8842-16MBL

Manufacturer Part Number
KSZ8842-16MBL
Description
2-Port Ethernet Switch/Repeater + Generic (8, 16-bit) Bus Interface ( )
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8842-16MBL

Controller Type
Ethernet Switch Controller
Interface
PCI
Voltage - Supply
3.1 V ~ 3.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LFBGA
Number Of Primary Switch Ports
2
Internal Memory Buffer Size
32
Operating Supply Voltage (typ)
3.3V
Fiber Support
Yes
Integrated Led Drivers
Yes
Phy/transceiver Interface
MII
Power Supply Type
Analog/Digital
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
3.5V
Operating Supply Voltage (min)
3.1V
Operating Temperature Classification
Commercial
Data Rate
100Mbps
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
576-1635 - BOARD EVALUATION KSZ8842-16MVL576-1634 - BOARD EVALUATION KSZ8842-16MQL
Current - Supply
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
576-3076

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8842-16MBL
Manufacturer:
Micrel
Quantity:
227
Part Number:
KSZ8842-16MBL
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8842-16MBLI
Manufacturer:
Micrel
Quantity:
327
Part Number:
KSZ8842-16MBLI
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8842-16MBLI TR
Manufacturer:
Micrel Inc
Quantity:
10 000
Bank 51 Port 2 PHY Special Control/Status, LinkMD (0x00): P2SCSLMD
Micrel, Inc.
Bit
15
14-13
12
11
10
9
8-0
October 2007
Default
0
0x0
0
0
1
0
0x000
R/W
RO
RO
RW
SC
RW
RW
RW
RO
Description
Vct_10m_short
1 = Less than 10 meter short.
Vct_result
VCT result.
[00] = normal condition.
[01] = open condition has been detected in the
cable.
[10] = short condition has been detected in the
cable.
[11] = cable diagnostic test has failed.
Vct_en
VCT enable.
1 = the cable diagnostic test is enabled. It is self-
cleared after the VCT test is done.
0 = it indicates the cable diagnostic test is
completed and the status information is valid for
read
Force_lnk
Force link.
1 = force link pass.
0 = normal operation.
Pwrsave
Power-saving.
1 = disable power saving.
0 = enable power saving.
Remote (Near-End) Loopback (rlb)
1 = perform remote loopback at Port 2's PHY
(RXP2/RXM2 -> TXP2/TXM2, see Figure 16)
0 = normal operation
Vct_fault_count
VCT fault count.
The distance to the fault is approximately
0.4m*vct_fault_count.
110
Bit is same as:
Bank 47 0x04 bit 12
Bank 47 0x04 bit 14-13
Bank 47 0x04 bit 15
Bank 47 0x06 bit 3
Bank 47 0x06 bit 2
Bank 47 0x06 bit 1
Bank 47 0x04 bit 8-0
KSZ8842-16/32 MQL/MVL/MVLI/MBL
M9999-102207-1.9