5EFM1S TE Connectivity, 5EFM1S Datasheet - Page 4

no-image

5EFM1S

Manufacturer Part Number
5EFM1S
Description
POWER ENTRY MODULE, PLUG, 5A
Manufacturer
TE Connectivity
Series
Mr
Type
Filter/Fuse/Switchr
Datasheets

Specifications of 5EFM1S

Gender
Plug
Voltage Rating
250VAC
Current Rating
5A
Connector Mounting
Flange
Termination Type
Quick Connect
Inductance Min
93µH
Mounting Type
Flange
Connector Type
Power Entry
Rohs Compliant
Yes
Capacitance, Cx
0.01
Capacitance, Cy
0.005
Current, Leakage
0.5 mA
Current, Rating
5 A
Cut Out, Panel
3.27×1.15 "
Filter Type
IEC
Inductance
0.93 mH
Mount Method
Front
Number Of Poles
3
Resistance
1.5 Megohms (Discharge), 6000 Megohms (No Discharge)
Temperature, Operating
-10 to +40 °C
Termination
Faston
Tyco Part Number
2-6609129-3
Version
Standard
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5EFM1S
Manufacturer:
TE/泰科
Quantity:
20 000
Neutral
Hot
Hot
Note 1:
Note 2:
Note 3:
Note 4:
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Neutral
Neutral
Hot
Note 2
Power On/Off
Note 2
Power On/Off
Note 2
Jumper required if no input filter is used
Provision for dual Metric style fusing
On/off switch present only in “S” suffix models
When using a center-tapped transformer, the C-F winding should be the
low voltage (high current) winding and must be capable of handling the full
primary current in the 120V position
Note 3
Note 3
Power On/Off
K
L
Note 3
K
L
Note 1
Note 1
Note 1
Note 1
120V
H
J
120V
100V
H
J
240V
A
B
C
D
E
F
G
B
D
E
F
K
G
L
230V
240V
Transformer Primaries
A
B
C
D
E
F
G
Transformer Primaries
Transformer Primaries
120V
120V
K
L
Customer
A
C
D
E
F
Customer
Customer
120V
100V
120V
20V
A
C
F
Note 4
120V
120V
Phase
Phase
Note 1:
Note 2:
Note 3:
Note 4:
Neutral
Neutral
Neutral
Phase
Phase
Neutral
Power On/Off
Note 1
Note 1
Provision for dual Metric style fusing
On/off switch present only in “S” suffix models
Line to ground capacitor not present on HM models
Models HM4, FM4, XM4 and ZM4 have added terminals K and L.
External switch or jumper must be placed from K to H and L to J
Power On/Off
Note 2
Note 2
Note 2
Note 3
Power On/Off
Note 2
Note 3
Power On/Off
Note 1
K
L
K
L
Note 1
Note 4
Note 4
Note 4
Note 4
120V
100V
120V
100V
H
J
H
J
H
J
H
J
230V
240V
B
A
C
D
E
F
G
B
F
G
230V
240V
B
F
G
B
C
A
D
E
F
G
Transformer Primaries
Transformer Primaries
C
D
A
E
F
C
D
A
E
F
Customer
Customer
120V
100V
120V
20V
100V
20V

Related parts for 5EFM1S