M290996 Multicore, M290996 Datasheet - Page 2

no-image

M290996

Manufacturer Part Number
M290996
Description
NO-CLEAN DESOLDER WICK 10'X0.06"
Manufacturer
Multicore
Type
No Cleanr
Datasheet

Specifications of M290996

Width
0.060" (1.50mm)
Length
10' (3.048m)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
82-149
Employers should complete an assessment of all workplaces to determine the need for, and selection of, proper exposure
controls and protective equipment for each task performed.
Hazardous components
Copper
IDH number: 290996
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected
Eye contact:
Ingestion:
Flash point:
Autoignition temperature:
Flammable/Explosive limits - lower:
Flammable/Explosive limits - upper:
Extinguishing media:
Special firefighting procedures:
Unusual fire or explosion hazards:
Hazardous combustion products:
Environmental precautions:
Clean-up methods:
Handling:
Storage:
Engineering controls:
Respiratory protection:
Eye/face protection:
For information on product shelf life contact Henkel Customer Service at (800) 243-4874.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
6. ACCIDENTAL RELEASE MEASURES
5. FIRE FIGHTING MEASURES
7. HANDLING AND STORAGE
Cu) Dust and mist.
1 mg/m3 TWA (as
0.2 mg/m3 TWA
ACGIH TLV
Flush eye(s) immediately with plenty of water. If eye irritation persists, consult
a specialist.
Wire strands could cause internal injury Induce vomiting immediately and call
a physician.
Not applicable
Not available
Not available
Not available
Will not burn. Do not use water on molten metal.
Firefighters should wear self-contained breathing apparatus. Water may be
ineffective, but may be used to cool exposed containers to prevent pressure
build-up and possible auto-ignition or explosion when exposed to extreme
heat. If water is used, fog nozzles are preferable.
None
High temperatures may produce heavy metal dust, fumes or vapors. The flux
medium will give rise to irritating fumes.
Do not allow product to enter sewer or waterways.
Scrape up as much material as possible.
Wash thoroughly after handling.
No special procedures.
Ensure adequate ventilation.
Use NIOSH approved respirator if there is potential to exceed exposure
limit(s).
Safety goggles or safety glasses with side shields.
Fume.
personnel.
Page 2 of 5
Cu) Dust and mist.
1 mg/m3 TWA (as
0.1 mg/m3 TWA
(as Cu) Fume.
OSHA PEL
Product name: NC-AA desoldering wick
AIHA WEEL
None
OTHER
None