FLUKE-77-4 Fluke Electronics, FLUKE-77-4 Datasheet - Page 16

MULTIMETER INDUSTRIAL 1000V CAT

FLUKE-77-4

Manufacturer Part Number
FLUKE-77-4
Description
MULTIMETER INDUSTRIAL 1000V CAT
Manufacturer
Fluke Electronics
Series
77 IVr
Type
Digital (DMM)r
Datasheet

Specifications of FLUKE-77-4

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2727486
614-1085
77-4
FLUKE-77-4
Model 77 Series IV
Users Manual
12
AC Volts (Average
responding)
DC mV
DC Volts
Continuity
Ohms
Diode test
Capacitance
AC Amps (Average
responding)
[1]
[2]
[3]
[4]
Function
In the 9999 F range for measurements to 1000 F, the measurement accuracy is 1.2 % + 2.
Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10 A input 37 mV/A.
400.0 mA accuracy specified up to 600 mA overload.
>10 A unspecified.
[2]
6.000 V
60.00 V
600.0 V
1000 V
600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
600
600.0
6.000 k
60.00 k
600.0 k
6.000 M
50.00 M
2.400 V
1000 nF
10.00 F
100.0 F
9999 F
60.00 mA
400.0 mA
6.000 A
10.00 A
[4]
[
1]
[3]
Range
0.001 V
0.01 V
0.1 V
1 V
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
1
0.1
0.001 k
0.01 k
0.1 k
0.001 M
0.01 M
0.001 V
1 nF
0.01 F
0.1 F
1 F
0.01 mA
0.1 mA
0.001 A
0.01 A
Resolution
Meter beeps at <25
detects opens or shorts of 250 s or longer.
2.0 % + 2
(45 Hz to 1 kHz)
0.3 % + 1
0.3 % + 1
0.5 % + 2
0.5 % + 1
0.5 % + 1
0.5 % + 1
0.5 % + 1
2.0 % + 1
1 % + 2
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
2.5 % + 2
(45 Hz to 1 kHz)
Accuracy ± ( [ % of Reading ] + [ Counts ] )
, beeper turns off at >250
;