Specifications of FLUKE-83-5

Includes
Battery, Clips, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
20000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Clips, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2075004
614-1086
83-5
FLUKE-83-5
(while in MIN MAX mode)
(hold for 1 second)
PEAK MIN MAX
D
B
B
E
B
Button
Enter MIN MAX recording mode. The Meter is locked in the range displayed before you
entered MIN MAX mode. (Select the desired measurement function and range before
entering MIN MAX.) The Meter beeps each time a new minimum or maximum value is
recorded.
Step through maximum (MAX), minimum (MIN), average (AVG) and present values.
Model 87 only: Select 100 ms or 250 s response time. (The 250 µs response time is
indicated by pon the display.) Stored values are erased. The present and AVG
(average) values are not available when 250 s is selected.
Stop recording without erasing stored values. Press again to resume recording.
Exit MIN MAX mode. Stored values are erased. The Meter stays in the selected range.
Table 7. MIN MAX Functions
MIN MAX Function
Smooth Feature (Power Up Option Only)