265 TPI (Test Products Int), 265 Datasheet - Page 14

no-image

265

Manufacturer Part Number
265
Description
DIGITAL CLAMP W/CAPACITANCE/FREQ
Manufacturer
TPI (Test Products Int)
Series
265r
Type
Digital (DMM)r
Datasheets

Specifications of 265

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
3.75
Display Type
LCD
Display Count
4000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Hold
Ranging
Auto/Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
265
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
265-118ABHE-22
Manufacturer:
WAK
Quantity:
4 472
Part Number:
26502401A
Manufacturer:
GIC
Quantity:
716
Part Number:
2651MTC-3.3
Manufacturer:
NSC
Quantity:
25
Part Number:
2652
Quantity:
5 510
Part Number:
2652
Manufacturer:
ST
Quantity:
5 510
Part Number:
2652C
Manufacturer:
TI
Quantity:
1 000
Part Number:
2652C
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
26553-I02
Manufacturer:
KNOWLES
Quantity:
20 000
Part Number:
26561
Manufacturer:
ST
0
2. Step by Step Procedures:
Measuring DC Voltage
Instrument set-up:
FUNC.
Measurement Procedure:
1. Disconnect power to circuit to be measured.
2. Plug black test lead into the COM input jack.
3
4. Set rotary switch to the V range.
5. Connect test leads to circuit to be measured.
6. Reconnect power to circuit to be measured.
7. Read the voltage on the 265.
Optional Modes
14
Plug red test lead into the V/
HOLD:
RANGE: Activates manual ranging. Press and hold for
than 600V or of a voltage level that is unknown. Make sure
the temperature probe is NOT plugged in during this test.
WARNING!
Do not attempt to make a voltage measurement of more
BLACK
TEST LEAD TEST LEAD
COM
Freezes the reading on the LCD.
2 seconds to return to auto ranging.
RED
V/Ω
MIN
READING
0.1mV
input jack.
MAXI
600V
READING