291 TPI (Test Products Int), 291 Datasheet - Page 7
Specifications of 291
Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
3.75
Display Type
LCD
Display Count
4000
Function
Voltage, Current, Resistance
Functions, Extra
Continuity
Features
Hold
Ranging
Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
291-H36AB
Manufacturer:
WAK
Quantity:
4 909
Part Number:
29102C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29103C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29104C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29105C
Manufacturer:
MURATA/村田
Quantity:
20 000
Company:
Part Number:
2911-0033
Manufacturer:
MOLEX
Quantity:
930
Company:
Part Number:
2911-0042
Manufacturer:
N/A
Quantity:
42 425
Company:
Part Number:
2911-0042
Manufacturer:
SMD
Quantity:
35 000
2. Product Applications
Perform the following tests and/or measurements with
the 291 and the appropriate function:
HVAC/R
ACA
ACV
ACV or DCV • Control circuit voltage.
OHMS
OHMS
OHMS
ACA
OHMS
ALL
ELECTRICAL
ACV
ACA
OHMS
DCV
ACA
ELECTRONIC
ACV
ACA
OHMS
• Heat anticipator current in thermostats.
• Line voltage.
• Heating element resistance (continuity).
• Compressor winding resistance.
• Contactor and relay coil resistance.
• Motor and compressor start up current.
• Continuity of wiring.
• Bar graph to indicate rapid fluctuations.
• Measure line voltage.
• Measure line current.
• Continuity of circuit breakers.
• Voltage of direct drive DC motors.
• Start up current of motors, relays,
• Measure power supply voltage.
• Measure power supply current.
• Continuity of circuit breakers and fuses.
contactors and transformers.