ACDC-100 TRMS Amprobe, ACDC-100 TRMS Datasheet - Page 2

DIGITAL CLAMP ON METER TRMS

ACDC-100 TRMS

Manufacturer Part Number
ACDC-100 TRMS
Description
DIGITAL CLAMP ON METER TRMS
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACDC-100 TRMS

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
3.75
Display Type
LCD
Display Count
4000
Function
Voltage, Current, Resistance, Capacitance
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Hold, Max
Ranging
Auto/Manual
Response
True RMS
Dmm Type
Clamp
Voltage Measuring Range Dc
400mV To 600V
Voltage Measuring Range Ac
400mV To 600V
Current Measuring Range Dc
0A To 1000A
Current Measuring Range Ac
400A To 800A
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
2740465
705-1012
1000A ACDC-100 AC/DC Clamp-On Multimeter
Electrical Specifications
Amprobe® Test Tools
Function
DC Voltage
NMRR :
CMRR :
Input Impedance :
AC Voltage
CMRR :
Input Impedance:
1)
Resistance
Audible Continuity Tester
Diode Tester
Open Circuit Voltage
< 1.6 VDC
Capacitance
1)
2)
3)
warning voltage of approximately 2.4V
DC Current (Clamp-on)
1) Induced error from adjacent current-carrying conductor: < 0.01A/A
2) ∆ Zero mode must be applied to zero the unit before measurement to ensure accuracy. This is particularly important below 20A.
Selection by RANGE button manually, and is specified from AC 40mV and up
Additional 50.00nF range accuracy is not specified
Accuracies with film capacitor or better
Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery
50Hz ~ 500Hz
50Hz ~ 60Hz
60Hz ~ 500Hz
50Hz ~ 500Hz
Open Circuit Voltage :
Open Circuit Voltage:
Range: 400.0Ω; Accuracy:
Audible threshold:
400.0A
1000A
Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23℃ ± 5℃ & less than 75% R.H.
Range
400.0 mV
4.000V, 40.00V, 400.0V
600V
>50dB @ 50/60Hz
>120dB @ DC, 50/60Hz, Rs=1kΩ
10MΩ, 30pF nominal (1000MΩ for 400.0mV range)
400.0mV 1)
4.000V, 40.00V, 400.0V
4.000V, 40.00V, 400.0V
600V
>60dB @ DC to 60Hz, Rs=1kΩ
10MΩ, 30pF nominal
400.0Ω
4.000kΩ, 40.00kΩ, 400.0kΩ
4.000MΩ
40.00MΩ
0.4VDC typical
0.4VDC typical
1.5% + 6d
between 10Ω and 120Ω.
Test Current (Typical)
0.4mA
500.0nF, 5.000μF, 50.00μF,
500.0μF, 3000μF
0.0A ~ 400.0A
400A ~ 800A
800A ~ 900A
900A ~ 1000A
1)
Accuracy
0.3% + 3d
0.5% + 3d
1.0% + 4d
4.0% + 4d
1.0% + 4d
1.5% + 4d
2.0% + 4d
0.8% + 6d
0.6% + 4d
1.0% + 4d
2.0% + 4d
1.5% + 4d
1.5% + 4d
2.0% + 4d
5.0% + 30d
3.5% + 6d
1) 2)
1) 2)
1) 2)
www.Amprobe.com
2) 3)
1) 2)
Data Sheet