FLUKE-87-5-EX Fluke Electronics, FLUKE-87-5-EX Datasheet - Page 31

no-image

FLUKE-87-5-EX

Manufacturer Part Number
FLUKE-87-5-EX
Description
MULTIMETER INDUSTRIAL TRU RMS
Manufacturer
Fluke Electronics
Series
8xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-87-5-EX

Includes
Battery, Clips, Temperature Probe, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
20000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Clips, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2547226
Measuring Capacitance
The Meter's capacitance ranges are 10.00 nF, 100.0 nF,
1.000 F, 10.00 F, 100.0 F, and 9999 F.
To measure capacitance, set up the Meter as shown in
Figure 6.
To improve the accuracy of measurements less than
1000 nF, use the relative (REL) mode to subtract the
residual capacitance of the Meter and leads.
To avoid possible damage to the Meter or to
the equipment under test, disconnect circuit
power and discharge all high-voltage
capacitors before measuring capacitance.
Use the dc voltage function to confirm that
the capacitor is discharged.
If too much electrical charge is present on the
capacitor being tested, the display shows
“diSC“.
WCaution
Note
Capacitance
Select
Figure 6. Measuring Capacitance
1 Second
Hi Res
Ex-Area:
Ui = 65 V
Ii = 5 A
Ta = -20 C ... +50 C
OFF
A
V
10A MAX
FUSED
V
PEAK MIN MAX
MIN MAX
mA
A
FUSED
400mA
RANGE
Observe reverse side of unit!
˚
REL
COM
C/
Geräterückseite beachten!
˚
ZELM 05 ATEX 0274
F
CAT
+
+
+
+
+
+
+
+
CAT
1000
mA
AutoHOLD
V
600V
A
Hz %
V
+
A
Making Measurements
True-rms Multimeter
ecg10f.eps
23