DMM AUTORANGING

15XP-A

Manufacturer Part Number
15XP-A
Description
DMM AUTORANGING
Manufacturer
Amprobe
Series
Magne-Grip™r
Type
Digital (DMM)r
Datasheet

Specifications of 15XP-A

Includes
Battery, Hanger, Test Leads
Style
Handheld
Display Digits
3.5
Display Type
LCD
Display Count
2000
Function
Voltage, Current, Resistance
Functions, Extra
Continuity, Diode Test, Logic
Features
Auto Off, Hold, Voltage Indicator
Ranging
Auto/Manual
Response
Average
Accuracy
+/- 0.5 %
True Rms
No
Min / Max Hold
No
Peak Hold
No
Data Hold
Yes
Resistance Range
200 Ohms to 2000 M Ohms
Frequency
20 MHz
Equipment Type
Digital Multimeter
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
2727836
705-1000
15XP-A Digital Multimeter
General Specifications
Specifications
Amprobe® Test Tools
Display
Polarity
Overrange
Zero
Low Battery Indication
Auto Power Off
Measurement Rate
Operating Environment
Storage Temperature
Accuracy
Temperature Coefficient
Altitude
Power
Battery Life
Dimensions
Weight
Warranty
Function
Voltage
Current
Resistance
Continuity
DC Volts
AC Volts (45 Hz to 500 Hz)
Resolution
Input Impedance
Overload Protection
DC Current
AC Current (45 Hz to 500 Hz)
Resolution
Input Protection
Burden Voltage
Resolution
Open Circuit Voltage
Overload Protection
Audible Indication
Response Time
Overload Protection
Ranges
Ranges
Ranges
Ranges
3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
Automatic, positive implied, negative polarity indication
(OL) or (-OL) is displayed
Automatic
The ”M” is displayed when the battery voltage drops below the operating level
Approx. 10 minutes
2 times per second, nominal
0 °C to 50 °C at <70 % R.H.
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity
0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C)
2000 m
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
200 hours typical with carbon-zinc
(H x W x D) 155 mm x 72 mm x 32 mm
Approx. 210 g including battery
One-year
200 mV, 2 V, 20 V, 200 V, 1000 V
200 mV (45 Hz to 100 Hz)
2 V, 20 V, 200 V, 750 V
100 μV
400 mV: >100 MW; 4 V: 10 MW; 40 V to 1000 V: 9.1 MW
1000 V DC or 750 V AC RMS
200 μA, 2000 μA, 20 mA, 200 mA
2 A
200 μA, 2000 μA, 20 mA, 200 mA
2 A
0.1 μA
2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input
500 mV max. (2 V max. on 2 mA, 200 mA ranges)
200 W, 2 kW, 20 kW, 200 kW, 2 MW
2000 MW
100 mW
-0.45 V DC typical, (-1.2 V DC on 200 W range)
1000 V DC or 750 V AC RMS
Less than 25 W
100 ms
1000 V DC or 750 V AC RMS
Range
± (0.5 % rdg + 1 dgt)
± (1.5 % rdg + 5 dgts)
± (1.5 % rdg + 5 dgts)
± (1.0 % rdg + 2 dgt)
± (2.0 % rdg + 3 dgts)
± (1.5 % rdg + 5 dgts)
± (2.5 % rdg + 5 dgts)
± (1.0 % rdg + 4 dgts)
± {5.0 % (rdg -10 dgts) +20 dgt}
Accuracy
www.Amprobe.com