TL221 Fluke Electronics, TL221 Datasheet - Page 66
![no-image](/images/no-image-200.jpg)
TL221
Manufacturer Part Number
TL221
Description
TEST LEAD EXTENSION SET SUREGRIP
Manufacturer
Fluke Electronics
Series
SureGrip™r
Type
Test Leadr
Datasheet
1.BP880.pdf
(72 pages)
Specifications of TL221
1st Connector
Receptacle, Female Sockets
2nd Connector
Receptacle, Female Sockets
Cable Type
Straight
Length
59.055" (1500.00mm)
Color
Black and Red
Contents
2 Leads
Wire Insulation Material
Silicone
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
2003602
FETL221
FETL221
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
TL2217-285N
Manufacturer:
HIT
Quantity:
6 221
Company:
Part Number:
TL2218-285PWLE
Manufacturer:
ON
Quantity:
4 524
Part Number:
TL2218-285PWLE
Manufacturer:
TI/德州仪器
Quantity:
20 000
Company:
Part Number:
TL2218-285PWR
Manufacturer:
STM
Quantity:
19 037
Part Number:
TL2218-285PWR
Manufacturer:
TI/德州仪器
Quantity:
20 000
66
1
* Requires PM9081/001 or BP880 Adapters
For more information and detailed specifications, go to www.fluke.com/accessories
Accessories
AC current
range
Accuracy
Bandwidth
(-3 dB)
Maximum con-
ductor diameter
Maximum
conductor size
Output levels
Output cable
Warranty
Safety rating
Meter
compatability
10/11/12/
12B/16/18
110/111/112
114/115/116/
117
21/23/73/75/77
Series III
26/79 Series III
27
70 Series III
175/177/179
1577/1587
Insulation Meter
83-III, 83-V,
88V
85/87 Series III
87 Series V
87/89 Series IV
187/189
8060A/8062A
DMMs
860 Series
Graphical
Multimeter
43B Power
Meter
433/434 Power
Quality
9X ScopeMeter
123/124
ScopeMeter
190 Series
ScopeMeter
45 DMM
74X Series
Process
Calibrators
787/789
ProcessMeter
Current and watt readings will be multiples of 10 higher or lower than actual.
AC current clamp specifications
(115, 117 only)
60 A to 200 A
50 A to 200 A
banana plugs
A48 to 65 Hz
CAT III 600 V
1 A to 200 A
1 A to 200 A
1 A to 200 A
3 A to 200 A
3 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
< 3 % +0.5
1 A to 40 A
300 MCM
shrouded
One-year
40 Hz to
1.5 A to
20 mm
(0.8 in)
1 mA/A
40 kHz
100 A
i00
1.5 m
For use with DMMs, scopeMeters
< 1 % +0.5 A
CAT III 600 V
1 A to 200 A
1 A to 200 A
1 A to 200 A
3 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
1 A to 200 A
2 m to BNC
termination
100 mV/A
300 MCM
One-year
Fluke current clamps
10 mV/A
200 A ac
48 Hz to
40 Hz to
1.1 A to
40 kHz
20 mm
(0.8 in)
i00s
65 Hz
1 A to
200 A
1
and power quality analyzers
(115, 117 only)
60 A to 400 A
50 A to 400 A
2 % + 0.06 A
banana plugs
CAT IV 600 V
and 200 A to
1 A to 400 A
1 A to 400 A
1 A to 400 A
3 A to 400 A
3 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 40 A
750 MCM
shrouded
One-year
45 Hz to
5 kHz to
(1.25 in)
1.5 A to
1 mA/A
1000 V
400 Hz
20 kHz
32 mm
CAT III
1.5 m
400 A
100 A
i00
30 A to 400 A
.015 A, 5 A to
400 A, 2 % +
3 A to 400 A*
3 A to 400 A*
2.5 m to BNC
CAT IV 600 V
.5 A to 40 A,
1 A to 400 A
0.6 A to 400
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
1 A to 400 A
.04 A, 45 to
termination
750 MCM
One-year
0.35 A to
(1.25 in)
10 mV/A
0.5 A to
1.1 A to
1 mV/A
1000 V
i00s
2 % +
400 Hz
5 Hz to
10 kHz
32 mm
400 A
CAT III
400 A
400 A
A ac*
AC range
50 A to 440 A
1 kHz 10 A to
banana plugs
60 A to 600A
1 A to 600 A
2 % 50 Hz to
CAT III 600 V
1 A to 600 A
and 200 A to
3 A to 600 A
3 A to 600 A
1 A to 600 A
1 A to 600 A
1 A to 600 A
1 A to 600 A
1 A to 600 A
1.5 A to 100
A and 500 A
48 to 65 Hz
2-500 MCM
1A to 600 A
80i-600A
1 A to 40 A
2 %+0.5 A
or 1-1000
1 %+1 A
10 mV/A
shrouded
One-year
100 A to
10 Hz to
(1.98 in)
to 600 A
1000 A:
50 mm
1 mA/A
100 A:
50 kHz
600 A
1.2 m
MCM
3 A to 1000 A*
0.2 A to 1000
CAT III 600 V
1.6 m to BNC
0.2 to 10 A:
48 to 65 Hz
2-500 MCM
termination
3 %+0.1 A
2 %+0.5 A
or 1-1000
100 mV/A
One-year
0.25 A to
0.15 A to
100 A to
1 %+1 A
10 mV/A
i1000s
1000 A:
100 kHz
(2.13 in)
1000 A*
1000 A*
1000 A*
1000 A*
1000 A*
1000 A*
1000 A*
1000 A*
1000 A*
1000 A*
1000 A*
1000 A
1000 A*
1000 A*
1000 A*
0.2 A to
1 mV/A
0.1 A to
0.1 A to
0.2 A to
0.1 A to
0.1 A to
1000 s*
0.3 A to
0.3 A to
0.1 A to
0.2 A to
0.1 A to
0.2 A to
0.3 A to
0.1 A to
0.3 A to
0.1 A to
0.1 A to
1.1 A to
0.2 A to
1000 A
10 A to
5 Hz to
54 mm
1000 A
1000 A
1000 A
1000 A
100 A:
A ac*
MCM
1
2 A to 2000 A
in) circumfer-
banana plugs
CAT III 600 V
i000 flex
45 to 65 Hz
Ranges: 20
60 mm (24
100 mV/A
2000 A ac
A, 200 A,
2 m with
shrouded
One-year
± 1 % of
10 mV/A
2000 A*
10 Hz to
177 mm
2000 A
4.5 A to
1 mV/A
2000 A
30 A to
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
2000 A
11 A to
2000 A
2000 A
20 kHz
double
ac rms
range
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
4 A to
5 A to
4 A to
4 A to
4 A to
4 A to
(7 in)
ence
1
(2.52 x 3.94 in)
1 A to 3000 A
64 x 100 mm
i000s flex
2.1 m to BNC
CAT III 600 V
1 to 3000 A:
2 % + 0.1 A
2 % + 0.5 A
1 to 300 A:
48 to 65 Hz
termination
610 mm or
1 to 30 A:
2 % + 2 A
3000 A ac
10 mV/A
0.1 mV/A
One-year
10 Hz to
100 kHz
915 mm
3000 A
1.2 A to
2.5 A to
1.5 A to
1 mV/A
3000 A
30 A to
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
11 A to
3000 A
3000 A
1 A to
1 A to
1 A to
2 A to
1 A to
1 A to
3 A to
3 A to
1 A to
2 A to
1 A to
2 A to
3 A to
1 A to
1 A to
1 A to
2 A to
1
AC only models
i200s
i400s
80i-600A
i1000s
i2000 flex
i3000s flex