TISP4030L1BJR-S Bourns Inc., TISP4030L1BJR-S Datasheet
TISP4030L1BJR-S
Specifications of TISP4030L1BJR-S
Related parts for TISP4030L1BJR-S
TISP4030L1BJR-S Summary of contents
Page 1
Low Capacitance ‘4015 ................................................................................... 28 pF ‘4030 ................................................................................... 27 pF ‘4040 ................................................................................... 23 pF Digital Line Signal Level Protection - ISDN - xDSL Safety Extra Low Voltage, SELV, values V V DRM (BO) Device V V ‘4015 ± 8 ± ...
Page 2
TISP40xxL1AJ/BJ VLV Overvoltage Protectors Absolute Maximum Ratings Repetitive peak off-state voltage Non-repetitive peak on-state pulse current (see Notes 1 and 2) 2/10 µs (T elcordia GR-1089-CORE, 2/10 µs voltage wave shape) 8/20 µs (IEC 61000-4-5, comb ...
Page 3
TISP40xxL1AJ/BJ VLV Overvoltage Protectors Electrical Characteristics Parameter MHz MHz Off-state capacitance off MHz, V Thermal Characteristics Parameter R Junctio n to free air thermal ...
Page 4
TISP40xxL1AJ/BJ VLV Overvoltage Protectors Parameter Measurement Information V DRM -v I DRM I (BO) V (BO) Quadrant III Switching Characteristic Figure 1. Voltage-Current Characteristic for T and R Terminals All Measurements are Referenced to the R Terminal +i I TSP ...
Page 5
TISP40xxL1AJ/BJ VLV Overvoltage Protectors Typical Characteristics OFF-STATE CURRENT vs JUNCTION TEMPERATURE 10000 1000 100 10 '4030L1 '4040L1 1 '4015L1 0 – Ambient Temperature – °C A Figure 2. ON-STATE CURRENT vs ON-STATE VOLTAGE ...
Page 6
TISP40xxL1AJ/BJ VLV Overvoltage Protectors Typical Characteristics CAPACITANCE vs OFF-STATE VOLTAGE 0.01 0.02 0.05 0.1 0.2 0 Off-state Voltage - V D Figure 6. Customers should verify ...
Page 7
TISP40xxL1AJ/BJ VLV Overvoltage Protectors Rating and Thermal Information AUGUST 1999 - REVISED JANUARY 2007 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. NON-REPETITIVE PEAK ON-STATE CURRENT vs CURRENT DURATION 30 V ...
Page 8
TISP40xxL1AJ/BJ VLV Overvoltage Protectors Transformer Protection The inductance of a transformer winding reduces considerably when the magnetic core material saturates. Saturation occurs when the magnetizing current through the winding inductance exceeds a certain value. It should be noted that this ...
Page 9
TISP40xxL1AJ/BJ VLV Overvoltage Protectors ® TISP Device Voltage Selection (Continued higher voltage protector might be chosen specifically to reduce the protector capacitive effects on the signal. Low energy short duration spikes will be clipped by the protector. This ...
Page 10
TISP40xxL1AJ/BJ VLV Overvoltage Protectors 4-Wire Digital Systems (Continued) SIGNAL T1 Th5 DC FEED SIGNAL For an HDSL d.c. feed voltage of 180 V or less and operation down to an ambient of -25 °C, the following Th1, ...
Page 11
TISP40xxL1AJ/BJ VLV Overvoltage Protectors Recommended Printed Wiring Land Pattern Dimensions SMA Land Pattern MILLIMETERS DIMENSIONS ARE: (INCHES) SMB Land Pattern MILLIMETERS DIMENSIONS ARE: (INCHES) Device Symbolization Code Devices will be coded as below. As the device parameters are symmetrical, terminal ...