TISP7240F3P-S Bourns Inc., TISP7240F3P-S Datasheet
TISP7240F3P-S
Specifications of TISP7240F3P-S
Related parts for TISP7240F3P-S
TISP7240F3P-S Summary of contents
Page 1
Patented Ion-Implanted Breakdown Region - Precise DC and Dynamic Voltages V DRM Device V ‘7125F3 100 ‘7150F3 120 ‘7180F3 145 ‘7240F3 180 ‘7260F3 200 ‘7290F3 220 ‘7320F3 240 ‘7350F3 275 ‘7380F3† 270 † For new designs use ‘7350F3 instead of ...
Page 2
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Description (continued) Each terminal pair has a symmetrical voltage-triggered thyristor characteristic. Overvoltages are initially clipped by breakdown clamping until the voltage rises to the breakover level, which causes the device to crowbar into a ...
Page 3
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Electrical Characteristics for all Terminal Pairs Parameter Repetitive peak off DRM D state current V Breakover voltage dv/dt = ±250 V/ms, R (BO) dv/dt ≤ ±1000 ...
Page 4
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Parameter Measurement Information V DRM -v I DRM I (BO) V (BO) Quadrant III Switching Characteristic Figure 1. Voltage-Current Characteristic for T and R Terminals T and G and R and G Measurements are ...
Page 5
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Typical Characteristics - R and and G Terminals TISP7125F3 THRU TISP7180F3 OFF-STATE CURRENT vs JUNCTION TEMPERATURE 100 10 1 0·1 0·01 0·001 - Junction Temperature - ...
Page 6
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Typical Characteristics - R and and G Terminals TISP7125F3 THRU TISP7180F3 NORMALIZED BREAKDOWN VOLTAGES vs JUNCTION TEMPERATURE 1.2 1.1 V (BO) V (BR)M 1.0 V (BR) I 0.9 - ...
Page 7
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Typical Characteristics - R and and G Terminals TISP7125F3 THRU TISP7180F3 ON-STATE CURRENT vs ON-STATE VOLTAGE 100 Negative Polarity 10 150 ° On-State Voltage - ...
Page 8
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Typical Characteristics - R and and G Terminals TISP7125F3 THRU TISP7180F3 NORMALIZED BREAKOVER VOLTAGE vs RATE OF RISE OF PRINCIPLE CURRENT 1.2 1.1 1.0 0·001 0·01 0·1 di/dt - Rate of ...
Page 9
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Typical Characteristics - R and T Terminals TISP7125F3 THRU TISP7180F3 OFF-STATE CURRENT JUNCTION TEMPERATURE 100 10 1 0·1 0·01 0·001 - Junction Temperature - °C J Figure 18. NORMALIZED ...
Page 10
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Typical Characteristics - R and T Terminals TISP7125F3 THRU TISP7180F3 ON-STATE CURRENT vs ON-STATE VOLTAGE 100 10 150 ° On-State Voltage - V T Figure 22. HOLDING CURRENT ...
Page 11
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Typical Characteristics - R and T Terminals TISP7125F3 THRU TISP7180F3 NORMALIZED BREAKOVER VOLTAGE vs RATE OF RISE OF PRINCIPLE CURRENT 1.2 1.1 1.0 0·001 0·01 0·1 di/dt - Rate of Rise of Principle Current ...
Page 12
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Thermal Information TISP7125F3 THRU TISP7180F3 MAXIMUM NON-RECURRING 50 Hz CURRENT vs CURRENT DURATION 10 1 0· Current Duration - s Figure 28. THERMAL RESPONSE 100 10 1 0·0001 0·001 0·01 ...
Page 13
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Thermal Information Non-repetitive peak on-state pulse current, 0 °C < T 1/2 (Gas tube differential transient, 1/2 voltage wave shape) 2/10 (Telcordia GR-1089-CORE, 2/10 voltage wave shape) 1/20 (ITU-T K.22, 1.2/50 voltage wave shape, ...
Page 14
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Deployment These devices are three terminal overvoltage protectors. They limit the voltage between three points in the circuit. Typically, this would be the two line conductors and protective ground (Figure 32) In Figure 32, ...
Page 15
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Lightning Surge (continued) ITU-T 10/700 Generator (continued 2 µF 50 Ω 10/700 GENERATOR - SINGLE TERMINAL PAIR TEST ...
Page 16
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Lightning Surge (continued) ITU-T 10/700 Generator (continued) The series resistance from individual output 27 Ω, giving an output conductance of 18 A/kV. For each 1 ...
Page 17
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Lightning Surge (continued) 1.2/50 Generators (continued) There are 8/20 short circuit current defined generators. These are usually very high current more and are used for testing a.c. protectors, primary protection modules ...
Page 18
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Protection Voltage The protection voltage, (V (BO) ), increases under lightning surge conditions due to thyristor regeneration. This increase is dependent on the rate of current rise, di/dt, when the TISP ® device is ...
Page 19
TISP7xxxF3 (MV, HV) Overvoltage Protector Series Typical Circuits TIP WIRE RING WIRE OVER- RING/TEST CURRENT PROTECTION PROTECTION TIP WIRE R1a Th3 COORDI- NAT ION Th1 RESISTANCE Th2 R1b RING WIRE TISP7xxxF3 F1a R1a Th3 GDTa Th1 GDTb Th2 F1b R1b ...