L6006V8 Littelfuse Inc, L6006V8 Datasheet
L6006V8
Specifications of L6006V8
Related parts for L6006V8
L6006V8 Summary of contents
Page 1
... Quadrants II and IV as well as control in the commonly used Quadrants I and III. Four-quadrant control devices require sensitive gate triacs. They can be controlled by digital circuitry where positive-only or negative-only pulses must control AC current in both directions through the device. Note that triacs with low I values in Quadrants II and IV will have lower dv/dt GT characteristics ...
Page 2
... Sensitive Triacs I Isolated T(RMS) (11) G MT1 MT1 MT2 MT2 G TO-92 Compak MAX See “Package Dimensions” section for variations. (12) L2X8E3 L2X3 L4X8E3 L4X3 L6X8E3 L6X3 L2X8E5 L2X5 L4X8E5 L4X5 0.8 A L6X8E5 L6X5 L2X8E6 L4X8E6 L6X8E6 L2X8E8 L4X8E8 L6X8E8 L201E3 L2N3 L401E3 ...
Page 3
... Sensitive Triacs 2 t dv/ di/dt gt (1) (9) Volts/µSec µSec Amps Sec Amps/µSec 100 °C TYP TYP 20 2.8 0. 2.8 0. 2 0.41 20 ...
Page 4
... L2006V5 L4006D5 L4006V5 L6006D5 L6006V5 L2006D6 L2006V6 L4006D6 L4006V6 L6006D6 L6006V6 L2006D8 L2006V8 L4006D8 L4006V8 L6006D8 L6006V8 L2008D6 L2008V6 L4008D6 L4008V6 L6008D6 L6008V6 L2008D8 L2008V8 L4008D8 L4008V8 L6008D8 L6008V8 General Notes = 50 mA with • All measurements are made with 60 Hz resistive load and ambient temperature of +25 ° ...
Page 5
... Gate Characteristics Teccor triacs may be turned on between gate and MT1 terminals in the following ways: with reference to MT1 • In-phase signals (with standard AC line) using Quadrants I and III • Application of unipolar pulses (gate always positive or nega- tive), using Quadrants II and III with negative gate pulses and ...
Page 6
... Sensitive Triacs Electrical Isolation Teccor’s isolated triac packages withstand a minimum high potential test of 2500 V ac rms from leads to mounting tab over the device's operating temperature range. The following isolation table shows standard isolation ratings. Electrical Isolation from Leads to Mounting Tab ...
Page 7
... Case Temperature ( ˚ versus Case Temperature 4.0 3.0 2.0 1.0 0 -65 -40 -15 +25 +65 Case Temperature ( ˚C C versus Case Temperature 7 ˚ MAX GT 5 MAX GT 4 MAX 3 MAX GT 2.0 1 100 DC Gate Trigger Current ( http://www.littelfuse.com +1 972-580-7777 Sensitive Triacs +110 +125 +110 +125 ...
Page 8
... Sensitive Triacs 200 SUPPLY FREQUENCY Sinusoidal 150 LOAD: Resistive RMS On-state Current: [I 100 Rated Value at Specified Case Temperature Figure E1.9 Peak Surge Current versus Surge Current Duration CURRENT WAVEFORM: Sinusoidal 1.5 LOAD: Resistive or Inductive CONDUCTION ANGLE: 360˚ 1 0.25 ...