D2VW-5L2-1HS Omron, D2VW-5L2-1HS Datasheet - Page 3

MINIATURE BASIC SWITCH

D2VW-5L2-1HS

Manufacturer Part Number
D2VW-5L2-1HS
Description
MINIATURE BASIC SWITCH
Manufacturer
Omron
Series
D2VWr
Type
Snap Actionr
Datasheets

Specifications of D2VW-5L2-1HS

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
5A @ 125VAC
Actuator Type
Lever, Roller
Mounting Type
Chassis Mount
Termination Style
Solder, Quick Connect - .187" (4.7mm)
Operating Force
120gf
Contact Form
SPDT
Contact Rating
3 Amps at 125 Volts, 250 Volts
Actuator
Lever, Hinge Roller
Body Style
Miniature
Current, Rating
5 A
Dielectric Strength
1500 VAC
Ip Rating
IP50
Mounting Hole Size
3.1 mm
Number Of Poles
1
Operation
Snap Action
Termination
Solder/Quick Connect
Voltage, Rating
250/30 VAC/VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D2VW5L21HS
SW437
D2VW
Specifications
Note:
Note:
D2VW-5
D2VW-01
Operating speed
Operating frequency
Insulation resistance
Contact resistance (initial value)
Dielectric strength (see note 2)
Vibration resistance (see note 3)
Shock resistance (see note 3)
Durability (see note 4)
Degree of protection
Degree of protection against electric shock
Proof tracking index (PTI)
Ambient operating temperature (see note 5)
Ambient operating humidity
Weight
Ratings
Characteristics
Model
The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
1. The data given above are initial values.
2. The dielectric strength shown in the table indicates the value for models with a Separator.
3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models,
4. For testing conditions, consult your OMRON sales representative.
they apply at the total travel position.
250 VAC
125 VAC
30 VDC
125 VAC
30 VDC
Rated voltage
Item
5 A
5 A
5 A
0.1 A
0.1 A
Resisteve load
0.1 mm to 1 m/s (pin plunger models)
Mechanical: 300 operations/min max.
Electrical:
100 MΩ min. (at 500 VDC)
50 mΩ max. (100 mΩ max. for molded lead wire models)
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal
parts
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 300 m/s
Mechanical: 10,000,000 operations min. (60 operations/min)
Electrical:
IEC IP67 (excluding the terminals on terminal models)
Class I
175
–40°C to 85°C (at ambient humidity of 60% max.) (with no icing or condensation)
95% max. (for 5°C to 35°C)
Approx. 7 g (pin plunger models with terminals)
30 operations/min max.
D2VW-5 models: 100,000 operations min. (30 operations/min)
D2VW-01 models: 1,000,000 operations min. (30 operations/min)
2
{approx. 30G} max.
2
{approx. 100G} max.
D2VW
3

Related parts for D2VW-5L2-1HS