ATV71HD90N4 SQUARE D, ATV71HD90N4 Datasheet - Page 4

no-image

ATV71HD90N4

Manufacturer Part Number
ATV71HD90N4
Description
SPEED DRIVE, 125HP, 460V, ATV71
Manufacturer
SQUARE D
Datasheet
Environment
Noise level
Dielectric strength
Electromagnetic compatibility
Standards
Product certifications
Pollution degree
IP degree of protection
Vibration resistance
Shock resistance
Relative humidity
Ambient air temperature for operation
Ambient air temperature for storage
Operating altitude
RoHS EUR status
4
60.5 dB conforming to 86/188/EEC
3535 V DC between earth and power terminals
5092 V DC between control and power terminals
1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3
Conducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3
Radiated radio-frequency electromagnetic field immunity test conforming to IEC
61000-4-3 level 3
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
EN 55011 class A group 2
EN 61800-3 environments 1 category C3
EN 61800-3 environments 2 category C3
EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3-3 class 3C2
UL Type 1
CSA
C-Tick
GOST
NOM 117
UL
2 conforming to EN/IEC 61800-5-1
3 conforming to UL 840
IP00 conforming to EN/IEC 60529
IP00 conforming to EN/IEC 61800-5-1
IP30 on side parts conforming to EN/IEC 60529
IP30 on side parts conforming to EN/IEC 61800-5-1
IP30 on the front panel conforming to EN/IEC 60529
IP30 on the front panel conforming to EN/IEC 61800-5-1
IP41 on upper part conforming to EN/IEC 60529
IP41 on upper part conforming to EN/IEC 61800-5-1
IP54 on lower part conforming to EN/IEC 60529
IP54 on lower part conforming to EN/IEC 61800-5-1
0.6 gn (f = 10...200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3...10 Hz) conforming to EN/IEC 60068-2-6
7 gn for 11 ms conforming to EN/IEC 60068-2-27
5...95 % without condensation conforming to IEC 60068-2-3
5...95 % without dripping water conforming to IEC 60068-2-3
-10...50 °C without derating
-25...70 °C
<= 1000 m without derating
1000...3000 m with current derating 1 % per 100 m
Will not be Compliant

Related parts for ATV71HD90N4