SR2D201FU SQUARE D, SR2D201FU Datasheet - Page 2

no-image

SR2D201FU

Manufacturer Part Number
SR2D201FU
Description
SR BL 20I-O 100-240VAC WC
Manufacturer
SQUARE D
Datasheet
Environment
Electrical durability
Switching capacity in mA
Operating rate in Hz
Mechanical durability
[Uimp] rated impulse withstand voltage
Clock
Response time
Connections - terminals
Tightening torque
Overvoltage category
Product weight
Immunity to microbreaks
Product certifications
Standards
IP degree of protection
Environmental characteristic
Disturbance radiated/conducted
Pollution degree
Ambient air temperature for operation
Ambient air temperature for storage
Operating altitude
Altitude transport
Relative humidity
2
500000 cycles AC-12 at 230 V, 1.5 A for relay output conforming to EN/IEC
60947-5-1
500000 cycles AC-15 at 230 V, 0.9 A for relay output conforming to EN/IEC
60947-5-1
500000 cycles DC-12 at 24 V, 1.5 A for relay output conforming to EN/IEC
60947-5-1
500000 cycles DC-13 at 24 V, 0.6 A for relay output conforming to EN/IEC
60947-5-1
>= 10 mA at 12 V (relay output)
0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay output
10000000 cycles (relay output)
4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
Without
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay output
50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50...255 ms with FBD programming (from state 0 to state 1) for discrete input
50...255 ms with FBD programming (from state 1 to state 0) for discrete input
Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 25...14 semi-solid
Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 25...14 solid
Screw terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm² AWG 24...14 flexible
with cable end
Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...16 solid
Screw terminals, clamping capacity: 2 x 0.25...2 x 0.75 mm² AWG 24...18 flexible
with cable end
0.5 N.m
III conforming to EN/IEC 60664-1
0.35 kg
<= 10 ms
CSA
C-Tick
GL
GOST
UL
EN/IEC 60068-2-27 Ea
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-11
EN/IEC 61000-4-12
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-6 level 3
IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529
EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2
Class B conforming to EN 55022-11 group 1
2 conforming to EN/IEC 61131-2
-20...40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC
60068-2-2
-20...55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
-40...70 °C
2000 m
<= 3048 m
95 % without condensation or dripping water

Related parts for SR2D201FU