50CPV240 Crydom Co., 50CPV240 Datasheet

IC,Normally-Open Panel-Mount Solid-State Relay,1-CHANNEL,M:HL048HD4.4

50CPV240

Manufacturer Part Number
50CPV240
Description
IC,Normally-Open Panel-Mount Solid-State Relay,1-CHANNEL,M:HL048HD4.4
Manufacturer
Crydom Co.
Series
CPVr
Datasheets

Specifications of 50CPV240

Circuit
SPST-NO (1 Form A)
Output Type
AC
Load Current
50A
Voltage - Input
0 ~ 5VDC
Voltage - Load
180 ~ 280 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Contact information visit our web site.
CPV Series
PRODUCT SELECTION
Description
120 VAC
240 VAC
OUTPUT SPECIFICATIONS (voltage) (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
OUTPUT SPECIFICATIONS (current) (1)
Description
Maximum Load Current (3) [Arms]
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I²t for Fusing (8.3 msec) [A² sec]
Minimum Power Factor (with Maximum Load)
CONTROL MODULE INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-Off Voltage
Typical Supply Current
Nominal Control Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
CONTROL MODULE OUTPUT SPECIFICATIONS (Terminal 4B - Input to Relay) (1)
Description
Maximum Off-State Operating Voltage
Maximum Load Current (Sink)
Maximum On-State Voltage @ 3 mA
Max. Off State Leakage @ 10 VDC
GENERAL SPECIFICATIONS
Description
Dielectric Strength, signal to load
Dielectric Strength, signal to Base
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
• Phase control modules
• 120/240 VAC models
• 0-5 V DC phase control
• Used with Series 1 random-fire solid-state relays
www.crydom.com
Themally Conductive Epoxy
90-140 VAC
120 VAC
1.6 mA @ 5 VDC
10CPV120
10CPV240
DC Control
DC Control
Parameters
10 A
10 A
-40 to 125°C
3.0 oz. (43g)
0.04
1.48
1500 Ohm
-30 to 80°C
400
500
120
1/2 Cycle
4000 Vrms
4000 Vrms
1.6
0.5
0-5 VDC
1.0 µADC
10
10
60
1.0 VDC
0.5 VDC
36 VDC
3.0 mA
0.02
180-280 VAC
240 VAC
25CPV120
25CPV240
25 A
25 A
0.04
1.02
600
500
250
260
1.6
0.5
10
25
Specifications subject to change without notice.
50CPV120
50CPV240
50 A
50 A
4150
0.04
0.31
625
1.6
0.5
75
75CPV120
75CPV240
75 A
75 A
1000
1620
0.04
0.63
1.6
0.5
50
©2008 Crydom, Inc.
90CPV120
90CPV240
90 A
90 A
1200
6000
0.04
0.28
1.6
0.5
90

Related parts for 50CPV240

50CPV240 Summary of contents

Page 1

... DC Control 36 VDC 3.0 mA 0.5 VDC 1.0 µADC Parameters 4000 Vrms 4000 Vrms -30 to 80°C -40 to 125°C 3.0 oz. (43g) Themally Conductive Epoxy www.crydom.com 50CPV120 75CPV120 90CPV120 50CPV240 75CPV240 90CPV240 0.04 0.04 0.04 625 1000 1200 1.6 1.6 0.31 0.63 0.28 4150 ...

Page 2

GENERAL NOTES 1) All parameters at 25°C unless otherwise spec ified. 2) Off-State dv/dt test method per EIA/NARM sta ndard RS-443, paragraph 13.11 Heat sinking required (relay only), see derating curves. AVAILABLE OPTIONS CPV120 Control Module Only (120 ...

Page 3

For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc. Specifications subject to change without notice. ...

Page 4

ANNEX - ENVIROMENTAL INFORMATION For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc. Specifications subject to change without notice. ...

Related keywords