50SST240 Crydom Co., 50SST240 Datasheet

IC,Normally-Open Panel-Mount Solid-State Relay,1-CHANNEL,M:HL048HD4.4

50SST240

Manufacturer Part Number
50SST240
Description
IC,Normally-Open Panel-Mount Solid-State Relay,1-CHANNEL,M:HL048HD4.4
Manufacturer
Crydom Co.
Series
SSTr
Datasheets

Specifications of 50SST240

Circuit
SPST-NO (1 Form A)
Output Type
AC
Load Current
50A
Voltage - Input
3.5 ~ 10VDC
Voltage - Load
180 ~ 280 V
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .187"/.250"
Package / Case
Hockey Puck
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SST Series
PRODUCT SELECTION
Description
120 Vrms Line Voltage
240 Vrms Line Voltage
OUTPUT SPECIFICATIONS (voltage) (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
OUTPUT SPECIFICATIONS (current) (1)
Description
Maximum Load Current (3) [Arms]
Minimum Load Current (3) [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I²t for Fusing (8.3 msec) [A²sec]
Minimum Power Factor (with Maximum Load)
CONTROL MODULE INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Maximum Off-State Voltage
Typical Input Current
Nominal Turn-On Delay time @ 60Hz
Nominal Swell (Ramp) Time @ 60Hz
Maximum Reset Time
Maximum Turn-Off Time [msec]
CONTROL MODULE OUTPUT SPECIFICATIONS (1)
Description
Maximum Off-State Operating Voltage
Maximum Load Current
Maximum Turn-On Voltage@ 3mA
Maximum Off-State Leakage@ 10 VDC
• Soft-start modules
• 120/240 V AC models
• 3.5-10 V DC control range
• Used with Series 1 random-fire solid-state relays
1.6 mA @ 5 VDC
10SST120
10SST240
DC Control
120 VAC
3.5-10 VDC
10 A
10 A
150 msec
180 msec
0.04
1.48
1/2 Cycle
120
0.1 msec
1.0 VDC
1.6
0.5
10
60
90-140
DC Control
400
500
10
1.0 µADC
3 mADC
0.5 VDC
36 VDC
25SST120
25SST240
25 A
25 A
0.04
1.02
250
260
1.6
0.5
25
240 VAC
180-280
600
500
10
40SST120
50SST240
50 A
50 A
1620
0.04
0.63
625
1.6
0.5
50
75SST240
75 A
75 A
1000
4150
0.04
0.31
1.6
0.5
75
90SST240
90 A
90A
1200
6000
0.04
0.28
1.6
0.5
90

Related parts for 50SST240

50SST240 Summary of contents

Page 1

... Maximum Turn-Off Time [msec] CONTROL MODULE OUTPUT SPECIFICATIONS (1) Description Maximum Off-State Operating Voltage Maximum Load Current Maximum Turn-On Voltage@ 3mA Maximum Off-State Leakage@ 10 VDC 10SST120 25SST120 40SST120 10SST240 25SST240 50SST240 120 VAC 240 VAC 90-140 180-280 400 600 10 10 500 500 ...

Page 2

GENERAL SPECIFICATIONS Description Dielectric Strength, signal to load Dielectric Strength, signal to Base Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Off-State dv/dt test method per ...

Page 3

THERMAL DERATE INFORMATION AGENCY APPROVALS UL E116949 Rev. 122010 ...

Page 4

...

Page 5

ANNEX - ENVIROMENTAL INFORMATION ...

Related keywords