I/O Module, G5, Digital Input DC, 5Vdc Logic, 2.5-16Vdc Load
Manufacturer
Grayhill Inc
Datasheet

Specifications of 70G-IDC5K

Lead Free Status / Rohs Status
RoHS Compliant part
FEATURES
• Transient Protection: Meets the
• Non-Polarized Types Provide
• UL, CSA, CE , TÜV Certified (TÜV
• Optical Isolation
• OpenLine
CIRCUITRY
SPECIFICATIONS: By Package Style
1
2
3
I/O
16
requirements of IEEE 472, “Surge
Withstanding Capability Test”*
Inputs For AC or DC
not available on OpenLine)
Built-in Status LED
Field to logic and channel-to-channel if Grayhill racks are used.
MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec
MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g.
Package Style
Specifications
Output Current Range
Min. Output Breakdown Voltage
Isolation Voltage
Vibration
Mechanical Shock
Storage Temp. Range
Operating Temp. Range
Warranty
2
®
and G5 Modules have
+
VDC
+VCC
OUTPUT
GROUND
Status LED in G5 modules only.
Standard, Mini, G5
1
3
1
2
3
4
5
AC/DC Input Modules
REGULATING
Rx
CURRENT
HYST. CIRC.
VOLTAGE
INPUT
Units
Vrms
Vdc
mA
°C
°C
TERMINAL
BLOCK #
SUPPLY
I/O MODULE
PIN #
DC
MIL-STD-202
MIL-STD-202
DEVICE
DEVICE
INPUT
INPUT
-40 to +125
-40 to +100
*
Std (70-)
Lifetime
70L-IDC
4000
1-50
50
1
2
3
4
BASE
RACK
OR
1
2
3
4
2
+/-
+/-
+/-
+/-
, 10-150 Hz.
70G-IDC
MIL-STD-202
MIL-STD-202
TYPICAL WIRING FOR MODULE 0
* Separate supplies may also be used.
Mini (70M-)
-40 to +125
-40 to +100
Lifetime
4000
1-50
50
FILTER
FILTER
OpenLine
ISOLATION
ISOLATION
OPTICAL
OPTICAL
MODULE
70-IDC
®
HYSTERESIS
MIL-STD-202
MIL-STD-202
-40 to +125
-40 to +100
G5 (70G-)
Lifetime
HYSTERESIS
4000
1-50
A
50
B
0Ω
70M-IDC
6
7
8
9
5
IEC68-2-27
-40 to +100
Vcc
CH. A STATUS
GND
CH. B STATUS
MODULE ID
OL (70L-)
IEC68-2-6
-40 to +85
Lifetime
2500
1-50
50

Related parts for 70G-IDC5K

70G-IDC5K Summary of contents

Page 1

... Lifetime 2 , 10-150 Hz. 70-IDC 70M-IDC ® 6 Vcc A 7 CH. A STATUS OPTICAL HYSTERESIS ISOLATION 5 GND B 8 CH. B STATUS OPTICAL HYSTERESIS ISOLATION 9 MODULE ID 0Ω MODULE G5 (70G-) OL (70L-) 1-50 1- 4000 2500 MIL-STD-202 IEC68-2-6 MIL-STD-202 IEC68-2-27 -40 to +125 -40 to +100 -40 to +100 -40 to +85 Lifetime Lifetime ...

Page 2

... Max. Logic Supply Current @ Nominal Vcc Module ID Resistance to Logic Ground 1 For input voltages in the range 140 Vdc, use AC input modules 70-IAC5, 70M-IAC5, 70G-IAC5 or 70L-IAC. For input voltages in the range of 180 to 280 Vdc, use AC input modules 70-IAC5A, 70M-IAC5A, 70G-IAC5A or 70L-IACA. Grayhill Part Number ...

Related keywords