ATV71HC40N4
variable speed drive ATV71 - 400KW 600HP -
480V - EMC filter
Main
Range of product
Product or component
type
Product specific appli-
cation
Component name
Motor power kW
Motor power hp
Motor cable length
Power supply voltage
Network number of
phases
Line current
EMC filter
Assembly style
Variant
Apparent power
Prospective line Isc
Nominal output current
Maximum transient cur-
rent
Speed drive output fre-
quency
Nominal switching fre-
quency
Switching frequency
Asynchronous motor
control profile
Type of polarization
Altivar 71
Variable speed drive
Complex, high-power machines
ATV71
355 kW at 380...480 V 3 phases
400 kW at 380...480 V 3 phases
600 hp at 380...480 V 3 phases
<= 100 m shielded cable
<= 200 m unshielded cable
380...480 V (- 15...10 %)
3 phases
512 A for 480 V 3 phases 355 kW
568 A for 480 V 3 phases 400 kW / 600 hp
637 A for 380 V 3 phases 355 kW
709 A for 380 V 3 phases 400 kW / 600 hp
Integrated
With heat sink
Reinforced version
419.3 kVA at 380 V 3 phases 355 kW
466.6 kVA at 380 V 3 phases 400 kW / 600 hp
<= 50 kA, 3 phases
671 A at 2.5 kHz 380 V 3 phases 355 kW
671 A at 2.5 kHz 460 V 3 phases 355 kW
759 A at 2.5 kHz 380 V 3 phases 400 kW / 600 hp
759 A at 2.5 kHz 460 V 3 phases 400 kW / 600 hp
1006 A for 60 s 3 phases 355 kW
1107 A for 2 s 3 phases 355 kW
1138 A for 60 s 3 phases 400 kW / 600 hp
1252 A for 2 s 3 phases 400 kW / 600 hp
0.1...500 Hz
2.5 kHz
2.5...8 kHz adjustable
2.5...8 kHz with derating factor
ENA (Energy adaptation) system for unbalanced
loads
Flux vector control (FVC) with sensor (current vec-
tor)
Sensorless flux vector control (SFVC) (voltage or
current vector)
Voltage/Frequency ratio (2 or 5 points)
No impedance for Modbus
1

Related parts for ATV71HC40N4

ATV71HC40N4 Summary of contents

Page 1

... Product data sheet Characteristics Apr 1, 2012 ATV71HC40N4 variable speed drive ATV71 - 400KW 600HP - 480V - EMC filter Main Range of product Altivar 71 Product or component Variable speed drive type Product specific appli- Complex, high-power machines cation Component name ATV71 Motor power kW 355 kW at 380...480 V 3 phases 400 kW at 380 ...

Page 2

Complementary Product destination Power supply voltage limits Power supply frequency Power supply frequency limits Speed range Speed accuracy Torque accuracy Transient overtorque Braking torque Synchronous motor control profile Regulation loop Motor slip compensation Diagnostic Output voltage Insulation Type of cable ...

Page 3

Analogue output type Discrete output number Discrete output type Minimum switching current Maximum switching current Discrete input number Discrete input type Discrete input logic Acceleration and deceleration ramps Braking to standstill Protection type Insulation resistance Frequency resolution Communication port protocol ...

Page 4

Product weight Option card Environment Noise level Dielectric strength Electromagnetic compatibility Standards Product certifications Pollution degree IP degree of protection Vibration resistance Shock resistance Relative humidity Ambient air temperature for operation Ambient air temperature for storage Operating altitude RoHS EUR ...

Page 5

... Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card. Dimensions with 2 Option Cards (1) Dimensions 890 392 417.5 Dimensions in in 35.04 15.43 16.44 (1) Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card. ATV71HC40N4 380 1120 2.95 14.96 44. ...

Page 6

... To ensure proper air circulation in the drive: ● Fit ventilation grilles. ● Ensure that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics). 6 ATV71HC40N4 X1 in in. 9. in. 11.81 ...

Page 7

Use special filters with IP 54 protection. ● Remove the blanking cover from the top of the drive. Dust and Damp Proof Metal Enclosure (IP 54) The drive must be mounted in a dust and damp proof enclosure in ...

Page 8

... Line choke (three-phase); mandatory for ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)). (2) For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal connections diagram. (3) Fault relay contacts. Used for remote signalling of the drive status. ...

Page 9

... Line choke (three-phase), mandatory for ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)). (2) For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal connections diagram. (3) Fault relay contacts. Used for remote signalling of the drive status. ...

Page 10

... Line choke (three-phase), mandatory for and ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)). (5) The logic output can be used to signal that the machine safe stop state. (6) For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal connections diagram. (7) Fault relay contacts. Used for remote signalling of the drive status. ...

Page 11

... The logic output can be used to signal that the machine safe state. (7) For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal connections diagram. (8) Fault relay contacts. Used for remote signalling of the drive status. ...

Page 12

... To circuit-breaker. (2) Line chokes, these are mandatory for ATV71HC40Y…HC63Y drives ordered separately. (3) DC chokes supplied as standard with ATV71HC40N4, HC50N4 drives. Not available for ATV71HC40Y…HC63Y. ( bus - ( bus + 12 ...

Page 13

... Performance Curves Derating Curves The derating curves for the drive nominal current (In) depend on the temperature and the switching frequency. For intermediate temperatures (e.g. 55°C), interpolate between 2 curves. Drive combined with a 355 kW motor X Switching frequency Drive combined with a 400 kW motor X Switching frequency ATV71HC40N4 13 ...

Related keywords