B3D-5112 Omron, B3D-5112 Datasheet - Page 4

5MM DOME

B3D-5112

Manufacturer Part Number
B3D-5112
Description
5MM DOME
Manufacturer
Omron
Series
B3Dr
Type
Tactile Switchesr
Datasheets

Specifications of B3D-5112

Circuit
SPST-NO
Switch Function
Off-Mom
Contact Rating @ Voltage
0.01A @ 12VDC
Actuator Type
Snap Dome
Mounting Type
Surface Mount
Orientation
Vertical
Illumination
Non-Illuminated
Operating Force
167gf
Contact Form
SPST - NO
Termination Style
Through Hole
Operating Temperature Range
- 40 C to + 80 C
Contact Voltage Dc Nom
12V
Contact Current Max
10mA
Actuation Type
Top
Switch Terminals
PCB / Push-on
Operating Force Min
1.18N
Operating Force Max
2.16N
Rohs Compliant
Yes
Actuator / Cap Color
White
Actuator Style
Dome
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
B3D5112
SW979
PCB Pattern Diagrams
B3D-4112
Precautions
■ Attaching to the PCB
Remove the Dome Key from the sheet using tweezers or a vacuum
pick-up tool, and attach it above the contact on the PCB surface,
which has been wiped clean in advance. Press down on the top sur-
face using an elastic material, such as urethane rubber, and a force
of 2.94 to 4.9 N. Place a positioning mark (circle) on the PCB for
easy positioning.
Make sure that the position of the Dome Key is aligned correctly
before use. Significant misalignment may result in short-circuits or
reduced sensitivity.
Note: The recommended vacuum pick-up tool is the Hozan P-835
Do not reuse a B3D Dome Key that has been detached from the
PCB. Attach a new Dome Key to the PCB.
Do not touch the contact dome with bare hands, or with unclean
gloves. Doing so may damage the contact dome, which is the part
that comes in contact with the PCB.
272
Vacuum Pick with an M suction pad (7-mm dia.).
Ultra-low Profile Dome Key
B3D
B3D-5112
■ Reflow Soldering
The Dome Key cannot withstand heat from reflow soldering. Always
perform reflow soldering before attaching the Dome Key to the PCB.
■ Washing
Do not wash the Dome Key. The Dome Key is not water-resistant and
must not be exposed to water or other liquids.
■ Common Precautions
Be sure to read the precautions common to all Tactile Switches,
contained in the Technical User’s Guide, “Tactile Switches, Technical
Information” for correct use.