D2S-10LD Omron, D2S-10LD Datasheet - Page 5

no-image

D2S-10LD

Manufacturer Part Number
D2S-10LD
Description
Subminiature Basic Switch
Manufacturer
Omron
Series
D2Sr
Datasheet

Specifications of D2S-10LD

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10.1A @ 250VAC
Actuator Type
Lever, Straight
Mounting Type
Through Hole
Termination Style
PC Pin
Operating Force
50gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D2S10LD
D2S
Precautions
Refer to General Information.
Terminal Connection
When soldering the lead wire to the terminal, first insert the lead
wire conductor through the terminal hole and then conduct sol-
dering.
Make sure that the capacity of the soldering iron is 60 W maxi-
mum. Do not take more than 5 s to solder the switch terminal.
Improper soldering involving an excessively high temperature or
excessive soldering time may deteriorate the characteristics of
the Switch.
When using automatic soldering baths, we recommend soldering
at 260±5°C within 5 seconds. Make sure that the liquid surface of
the solder does not flow over the edge of the board.
Cat. No. B092-E1-04
Cautions
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Mounting
Turn OFF the power supply before mounting or removing the
Switch, wiring, or performing maintenance or inspection. Failure
to do so may result in electric shock or burning.
Use M2.3 mounting screws with plane washers or spring washers
to securely mount the Switch. Tighten the screws to a torque of
0.23 to 0.26 N·m {2.3 to 2.7 kgf·cm}.
Mount the Switch onto a flat surface. Mounting on an uneven sur-
face may cause deformation of the Switch, resulting in faulty oper-
ation or breakage in the housing.
Operating Stroke Setting
Take particular care in setting the operating stroke for the pin
plunger models. Make sure that the operating stroke is 70% to
100% of the rated OT distance. Do not operate the actuator
exceeding the OT distance, otherwise the durability of the Switch
may be shortened.
Using Micro Loads
Using a model for ordinary loads to open or close the contact of a
micro load circuit may result in faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the operating range shown below, if inrush
current occurs when the contact is opened or closed, it may
increase contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary.
The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ 60). The equation, λ 60 = 0.5×10
indicates that the estimated malfunction rate is less than 1/
2,000,000 operations with a reliability level of 60%.
Correct Use
Inoperable
range
Operating range
for micro load
models D2S-01
Current (mA)
Operating
range for
general load
models
D2S-5,
D2S-10
–6
/operations
D2S
5