DZ-10GW-1B Omron, DZ-10GW-1B Datasheet

BASIC SWITCH

DZ-10GW-1B

Manufacturer Part Number
DZ-10GW-1B
Description
BASIC SWITCH
Manufacturer
Omron
Series
DZr
Datasheets

Specifications of DZ-10GW-1B

Circuit
DPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Lever, Straight
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
170gf
Contact Form
DPDT
Contact Rating
10 Amps at 250 Volts
Actuator
Lever, Hinge
Microswitch Type
Snap Action
Actuator Style
Hinge Lever
Operating Force Max
1.67N
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Current Max
10A
Switch Terminals
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
DZ10GW1B
DPDT Basic Switch for Two
Independent Circuit Control
• Ideal for switching the circuits operating on two
• Interchangeable with OMRON Z Basic Switches, as
Model Number Structure
Model Number Legend
DZ-10G @ -1 @
Ordering Information
Specifications
Ratings
Note: 1. The above values are for steady-state current.
Actuator
Pin plunger
Hinge lever
Short hinge roller lever
Hinge roller lever
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VAC
250 VDC
Rated voltage
different voltages, and for controlling two independent
circuits.
both switches are identical in mounting hole
dimensions, mounting pitch and pin plunger position.
Special-purpose Basic Switch
DZ
Accessories (Terminal Covers, Actuators, and Separators): Refer to Z/A/X/DZ Common Accessories and Z/X/DZ Common Accessories.
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The ratings values apply under the following test conditions:
(1) (2)(3) (4)(5)
Be sure to read Safety Precautions on page 4 and Safety
Precautions for All Basic Switches.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
Resistive load
NC
Non-inductive load (A)
0.25
10
10
10
10
10
0.5
NO
(1) Ratings
(2) Contact Gap
NC
1.5
Lamp load
2
3
3
3
Terminal
10
G
High OT
Low OT
High OT
Low OT
High OT
Low OT
0.25
0.5
: 10 A (250 VAC)
: 0.5 mm
NO
0.7
1.5
1.5
1.5
1
Inductive load
NC
Solder terminal (-1A)
0.05
0.03
6
4
6
6
4
Inductive load (A)
DZ-10GW22-1A
NO
DZ-10GV22-1A
DZ-10GW2-1A
DZ-10GV2-1A
DZ-10GW-1A
DZ-10GV-1A
DZ-10G-1A
Model
(3) Actuator
None : Pin plunger
V
V22 : Short hinge roller lever
V2
W
W22 : Short hinge roller lever
W2
NC
Motor load
3
2
5
5
3
: Hinge lever
: Hinge roller lever
: Hinge lever
: Hinge roller lever
0.05
0.03
NO
1.5
2.5
2.5
1.5
1
Certified Standard Ratings
Ask your OMRON representative for
information on certified models.
UL/CSA
Rated voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
Screw terminal (-B)
(4) Contact Form
(5) Terminals
DZ-10GW22-1B
DZ-10GV22-1B
DZ-10GW2-1B
DZ-10GV2-1B
DZ-10GW-1B
1
A
B
DZ-10GV-1B
DZ-10G-1B
Model
: DPDT
: Solder terminal
: Screw terminal
CSM_DZ_DS_E_2_1
10 A 1/8 HP
10 A 1/4 HP
DZ-10G
0.25 A
0.5 A
2 A
1

Related parts for DZ-10GW-1B

DZ-10GW-1B Summary of contents

Page 1

... CSM_DZ_DS_E_2_1 (4) Contact Form 1 : DPDT (5) Terminals A : Solder terminal B : Screw terminal Screw terminal (-B) Model DZ-10G-1B DZ-10GW-1B DZ-10GV-1B DZ-10GW22-1B DZ-10GV22-1B DZ-10GW2-1B DZ-10GV2-1B Certified Standard Ratings Ask your OMRON representative for information on certified models. UL/CSA Rated voltage DZ-10G 125 VAC 10 A 1/8 HP 250 VAC ...

Page 2

... Operating frequency: 240 operations/min 3,000 1,000 700 500 300 100 0 0.1 0.2 0.3 0.4 0.5 0.6 Overtravel (mm) Electrical Durability (DZ-10G-1B) 1,000 Ambient temperature: 20±2°C 700 Ambient humidity: 65±5%RH Operating frequency: 20 operations/min 500 cosφ=1 300 125 VAC 100 70 50 250 VAC 30 ...

Page 3

... Hinge Lever DZ-10GW-1B 19.7 17.7 DZ-10GV- 14.5 +0.075 4.2 -0.025 Short Hinge Roller Lever DZ-10GW22-1B 19.7 17.7 DZ-10GV22- 14.5 Hinge Roller Lever DZ-10GW2-1B 19.7 17.7 DZ-10GV2- 14.5 4.2 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions 28 14.5 8.2 +0.075 4.2 +0 ...

Page 4

... Incorrect Correct Accessories (Order separately) Refer to Z/A/X/DZ Common Accessories for details about Terminal Covers, Separators, and Actuators. • Do not use the switch in locations subject to hot water (greater than 60° water vapor. • Do not use the switch outside the specified temperature and atmospheric conditions ...

Page 5

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords