G9EC-1 DC100 Omron, G9EC-1 DC100 Datasheet - Page 4

DC Power Relay

G9EC-1 DC100

Manufacturer Part Number
G9EC-1 DC100
Description
DC Power Relay
Manufacturer
Omron
Series
G9EC-1r
Datasheet

Specifications of G9EC-1 DC100

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
200A
Switching Voltage
400VDC - Max
Coil Type
Standard
Coil Current
113mA
Coil Voltage
100VDC
Turn On Voltage (max)
75 VDC
Turn Off Voltage (min)
10 VDC
Mounting Type
Chassis Mount
Termination Style
Wire Leads
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
200A @ 400VDC
Control On Voltage (max)
75 VDC
Control Off Voltage (min)
10 VDC
Load Voltage Rating
400 VDC
Load Current Rating
200 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G9EC-1DC100
G9EC1DC100
4
1.4
1.2
0.8
0.6
0.4
0.2
1
0
The value at which malfunction occurred was
measured after applying shock to the test piece
3 times each in 6 directions along 3 axes.
Vibration Malfunction
1
Sample: G9EC-1
Number: 5
X
Z'
Shock Malfunction
Unit: m/s
Sample: G9EC-1
Number: 5
Deenergized
Confirmed area
5
DC Power Relays (200-A Models)
2
10
Y
Y'
800
600
400
200
200
400
600
800
1,000
1,000
50
Unconfirmed area
100
Y'
Energized
Frequency (Hz)
Y
X'
Z
X'
500
X
Z'
Z
1,000
−1.0
−2.0
−3.0
−4.0
−5.0
−1.0
−2.0
−3.0
−4.0
−5.0
Characteristics were measured after applying vibration
at a frequency of 10 to 55 Hz (single amplitude of 0.75
mm) to the test piece (not energized) for 2 hours each
in 3 directions. The percentage rate of change is the
average value for all of the samples
5.0
4.0
3.0
2.0
1.0
0.0
5.0
4.0
3.0
2.0
1.0
0.0
Characteristics were measured
of 490 m
along 3 axes
average value for all of the samples.
Shock Resistance
Vibration Resistance
Start
Start
Sample: G9EC-1
Number: 5
Sample: G9EC-1
Number: 5
2
/s to the test piece 3 times each in 6 directions
. The percentage rate of change is the
G9EC-1
Must-operate voltage
Must-release voltage
Must-release voltage
Must-operate voltage
after applying a shock
After test
After test

Related parts for G9EC-1 DC100