MY4H DC100/110 Omron, MY4H DC100/110 Datasheet

RELAY

MY4H DC100/110

Manufacturer Part Number
MY4H DC100/110
Description
RELAY
Manufacturer
Omron
Series
MY4Hr
Datasheets

Specifications of MY4H DC100/110

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
3A
Switching Voltage
125VAC, 125VDC - Max
Coil Type
Standard
Coil Current
8.2mA
Coil Voltage
110VDC
Turn On Voltage (max)
88 VDC
Turn Off Voltage (min)
11 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
3A @ 110VAC
Control On Voltage (max)
88 VDC
Control Off Voltage (min)
11 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MY4HDC100/110
MY4HDC100110
Hermetically Sealed Relay Ideal for
Hazardous Locations
• Class 1 Division 2 approved.
• Fully hermetically sealed for hazardous
• Cadmium-free contacts for environment-friendly use.
• Models with bifurcated contact also available.
• UL recognized / CSA certified.
Ordering Information
■ Model Number Legend:
1. Number of Poles
2. Contact
Specifications
■ Ratings
Coil
Hermetically sealed
DC
AC
locations.
Hermetically Sealed Relay
MY4H
Rated voltage (V)
4:
Z:
MY-❏❏❏ - ❏ - ❏
4 poles
Bifurcated
12
24
110/120
24
1 2 3
Type
4
75
36.9
9.9/10.8
53.8
5
Rated current (mA)
50 Hz
8.4/9.2
46
4PDT (bifurcated)
60 Hz
160
650
4,430
180
Coil resistance
Contact form
(Ω)
80% max.
Must operate
voltage
3. Enclosure ratings
4. Approval
5. Rated voltage
H:
US:
12 VDC, 24 VDC, 24 VAC, 110/120 VAC
Hermetically Sealed Relay
Hermetically sealed
Class 1 Division 2 approval
MY4ZH-US
10% min.
30% min.
Must release
voltage
Plug-in socket/solder terminals
110%
Max. voltage
Model
MY4H
900 mW
0.9-1.1 VA
(60 Hz)
consumption
Power
255

Related parts for MY4H DC100/110

MY4H DC100/110 Summary of contents

Page 1

Hermetically Sealed Relay MY4H Hermetically Sealed Relay Ideal for Hazardous Locations • Class 1 Division 2 approved. • Fully hermetically sealed for hazardous locations. • Cadmium-free contacts for environment-friendly use. • Models with bifurcated contact also available. • UL recognized ...

Page 2

Contact Ratings Contact material Rated load Resistive p.f.=1 Inductive p.f.=0.4 L/R-7 ms Rated carry current Max. switching voltage Max. switching current Max. switching power ■ Characteristics Contact resistance Operate time Release time Max. operating Mechanical frequency Electrical Insulation resistance Dielectric ...

Page 3

Characteristic Data Maximum Switching Power MY4ZH AC resistive load AC inductive load (cosφ=0.4) DC resistive load DC inductive load (L ms) Switching voltage (V) Dimensions Unit: mm ■ Solder Terminal Models MY4ZH Fourteen, 1.2-dia.×3, round holes 6.4. ...

Page 4

Socket Track-mounted Socket Conforming to Class 1 Division 2 • Special Socket with Class 1 Division 2 approval. • Holding clips contribute to safety by preventing the Relay falling out of the Socket due to vibration. Ordering Information Item ...

Page 5

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 6

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...