P2R-08P Omron, P2R-08P Datasheet - Page 3

PCB G2R-2S BACK CONN. SOCKET

P2R-08P

Manufacturer Part Number
P2R-08P
Description
PCB G2R-2S BACK CONN. SOCKET
Manufacturer
Omron
Series
G2RSr
Type
Socketr
Datasheets

Specifications of P2R-08P

Number Of Positions
8
Mounting Type
Through Hole
Termination Style
PC Pin
Associated Relay Series
G2R-2S
Number Of Poles
2
Accessory Type
Sockets
Socket Mounting
PC Board
Current Rating
5A
Socket Terminals
Through Hole
Voltage Rating
250VAC
No. Of Pins
8
Length/height, External
35.5mm
External Width
14.5mm
External Depth
36mm
Rohs Compliant
Yes
Contact Termination
Through Hole Vertical
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
G2R-2-S Relays
For Use With
G2R-2-SNIDC24(S) - RELAY DPDT 24VDC PLUG-IN W/LEDG2R-2-SNIDC12(S) - RELAY DPDT 12VDC PLUG-IN W/LEDG2R-2-SNIAC24(S) - RELAY DPDT 24VAC PLUG-IN W/LEDG2R-2-SNIAC230(S) - RELAY DPDT 230VAC PLUG-IN W/LEDG2R-2-SNIAC120(S) - RELAY DPDT 120VAC PLUG-IN W/LEDG2R-2-SNDIDC24(S) - RELAY DPDT 24VDC PLUG-IN W/LEDG2R-2-SNDIDC12(S) - RELAY DPDT 12VDC PLUG-IN W/LEDG2R-2-SNDDC6(S) - RELAY DPDT 6VDC PLUG-IN W/LEDZ2866 - RELAY PWR DPDT 5A 24VDC PLGG2R-2-SNDC48(S) - RELAY DPDT 48VDC PLUG-IN W/LEDG2R-2-SNAC240(S) - RELAY DPDT 240VAC PLUG-IN W/LEDG2R-2-SNAC230(S) - RELAY DPDT 230VAC PLUG-IN W/LEDG2R-2-SNAC12(S) - RELAY DPDT 12VAC PLUG-IN W/LEDG2R-2-SNAC110(S) - RELAY DPDT 110VAC PLUG-IN W/LEDG2R-2-SDDC6(S) - RELAY DPDT 5A 6VDC PLUG-ING2R-2-SDDC48(S) - RELAY DPDT 5A 48VDC PLUG-ING2R-2-SDDC24(S) - RELAY DPDT 5A 24VDC PLUG-ING2R-2-SDDC12(S) - RELAY DPDT 5A 12VDC PLUG-ING2R-2-SDC5(S) - RELAY GP DPDT 5A 5VDC PLUG-ING2R-2-SDC100(S) - RELAY GP DPDT 5A 100VDC PLUG-ING2R-2-SAC12(S) - RELAY GP DPDT 5A 12VAC PLUG-ING2R-2-SAC110(S) - RELAY GP DPDT 5A 110VAC PLUG-ING2R-2-SND-DC12S - RELAY PWR DPDT 5A 12VDC QC MNTZ2241 - RELAY DPDT 120VAC PLUG-IN W/LEDZ2240 - RELAY DPDT 24VAC PLUG-IN W/LEDZ2239 - RELAY DPDT 24VDC PLUG-IN W/LEDZ2238 - RELAY DPDT 6VDC PLUG-IN W/LEDZ2237 - RELAY DPDT 12VDC PLUG-IN W/LEDZ2231 - RELAY GP DPDT 48VDC PLUG-INZ2229 - RELAY GP DPDT 240VAC PLUG-INZ2225 - RELAY GP DPDT 6VDC PLUG-INZ1639 - RELAY PWR 120VAC 2POL SOCKET MNTZ1638 - RELAY PWR 24VAC 2POLE SOCKET MNTZ1637 - RELAY PWR DPDT 5A 24VDC QC MNTZ1636 - RELAY PWR DPDT 5A 12VDC QC MNT
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
P2R-08P
P2R08P
Z2605
■ Contact Ratings
Note: P level: λ
■ Characteristics
Note: Values in the above table are the initial values.
■ Approved Standards
UL Recognized (File No. E41643) - - Ambient Temp. = 40°C
CSA Certified (File No. LR31928)
Number of poles
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Minimum permissible load
Contact resistance
Operate (set) time
Release (reset) time
Max. operating
frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Service life
Ambient temperature
Ambient humidity
Weight
G2R-1-S SPDT
G2R-2-S DPDT
G2R-1-S SPDT
G2R-2-S DPDT
Model Contact
Model Contact
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used.
Item
form
form
60
= 0.1 x 10
5 to 110 VDC
5 to 240 VAC
5 to 110 VDC
5 to 240 VAC
Coil ratings
Coil ratings
100 mΩ max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
Mechanical:
Electrical:
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
Operating:
Operating:
Approx. 21 g
-6
/operation
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
Resistive load
(cosφ = 1)
10 A at 250 VAC;
10 A at 30 VDC
10 A
440 VAC, 125 VDC
10 A
2,500 VA,
300 W
100 mA at 5 VDC
Contact ratings
Contact ratings
18,000 operations/hr
1,800 operations/hr (under rated load)
5% to 85%
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
200 m/s
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
–40°C to 70°C (with no icing or condensation)
1 pole
2
when energized; 100 m/s
2
1 pole
Cycles
Cycles
6 x 10
6 x 10
6 x 10
6 x 10
Inductive load
(cosφ = 0.4; L/R = 7 ms)
7.5 A at 250 VAC;
5 A at 30 VDC
1,875 VA,
150 W
3
3
3
3
IEC/VDE (EN61810)
LR
Contact
1 pole
2 poles
1 pole
2 poles
Number
of poles
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
form
2
General-purpose Relay
when not energized
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 to 110 VDC
5 to 240 VDC
5 to 110 VDC
5 to 240 VDC
Coil ratings
Coil ratings
Resistive load
(cosφ = 1)
5 A at 250 VAC;
5 A at 30 VDC
5 A
380 VAC, 125 VDC
5 A
1,250 VA,
150 W
10 mA at 5 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
2 poles
Contact ratings
Contact ratings
G2RS-(S)
2 poles
Inductive load
(cosφ = 0.4; L/R = 7 ms)
2 A at 250 VAC; 3 A at
30 VDC
500 VA,
90 W
100 x 10
100 x 10
Cycles
100 x 10
100 x 10
Cycles
247
3
3
3
3