PYF08A Omron, PYF08A Datasheet

no-image

PYF08A

Manufacturer Part Number
PYF08A
Description
NEW P/N PYF08A-E
Manufacturer
Omron
Series
PYFr
Datasheets

Specifications of PYF08A

Accessory Type
Socket, Front Mounting
Associated Relay Series
MY
Number Of Poles
2
Termination Style
Screw
Mounting Style
DIN Rail
Width
22 mm
Socket Mounting
DIN Rail
Current Rating
7A
Socket Terminals
Screw
Voltage Rating
250VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PYF08A
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
PYF08A-E
Manufacturer:
OMRON
Quantity:
2 000
Part Number:
PYF08A-E
Manufacturer:
OMRON欧姆龙进口
Quantity:
20 000
Company:
Part Number:
PYF08A-E
Quantity:
1 655
Part Number:
PYF08A-K3FM
Manufacturer:
NEC
Quantity:
21
Part Number:
PYF08A-N
Manufacturer:
OMRON
Quantity:
100
Versatile, Multi-featured, Miniature Power Relay
for Sequence Control and Power Switching
Applications
• Models with lockable test buttons now available.
• Multiple features available, including operation indicators (mechan-
• Environment-friendly cadmium-free contacts.
• Wide range of Sockets (PY, PYF Series) and optional parts.
• Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A
• Provided with nameplate.
• RoHS Complaint.
Ordering Information
■ Relays
Standard Coil Polarity
Reverse Coil Polarity
Note: 1. When ordering, add the rated coil voltage to the model number(s), followed by “(S)”. Rated coil voltages are given in the coil ratings table.
Type
Standard
With built-in diode
(DC only)
With built-in CR
(220/240 VAC,
110/120 VAC only)
Type
Standard (DC only)
With built-in diode
(DC only)
ical and LED indicators), lockable test button, built-in diode and CR
(surge suppression), bifurcated contacts, etc.
General-purpose Relay
MY
2. Arc barrier standard on all four-pole relays.
3. Other models also available, such as, three-pole versions, flangemount, PCB, etc. Contact your Omron Representative for details.
Example: MY2 AC12(S)
Rated coil voltage
Contact form
DPDT
4PDT
4PDT (bifurcated)
DPDT
4PDT
4PDT (bifurcated)
DPDT
4PDT
4PDT (bifurcated)
Contact form
DPDT
4PDT
4PDT (bifurcated)
DPDT
4PDT
4PDT (bifurcated)
Model
Plug-in socket/solder terminals
Standard with LED
indicator
MY2N
MY4N
MY4ZN
MY2N-D2
MY4N-D2
MY4ZN-D2
MY2N-CR
MY4N-CR
MY4ZN-CR
Model
Plug-in socket/solder terminals
With LED indicator
MY2N1
MY4N1
MY4ZN1
MY2N1-D2
MY4N1-D2
MY4ZN1-D2
With LED indicator and
lockable test button
MY2IN
MY4IN
MY4ZIN
MY2IN-D2
MY4IN-D2
MY4ZIN-D2
MY2IN-CR
MY4IN-CR
MY4ZIN-CR
General-purpose Relay
With LED indicator and
lockable test button
MY2IN1
MY4IN1
MY4ZIN1
MY2IN1-D2
MY4IN1-D2
MY4ZIN1-D2
Without LED indicator
MY2
MY4
MY4Z
---
---
---
---
---
---
MY
LR
259

Related parts for PYF08A

PYF08A Summary of contents

Page 1

... Note: 1. When ordering, add the rated coil voltage to the model number(s), followed by “(S)”. Rated coil voltages are given in the coil ratings table. Example: MY2 AC12(S) ↑ Rated coil voltage 2. Arc barrier standard on all four-pole relays. 3. Other models also available, such as, three-pole versions, flangemount, PCB, etc. Contact your Omron Representative for details. Model Plug-in socket/solder terminals Standard with LED With LED indicator and ...

Page 2

... AC coil resistance and impedance are provided as reference values (at 60 Hz). 4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder re- sistor if required. 5. Rated voltage denoted by “*” will be manufactured upon request. Ask your OMRON representative. ■ Contact Ratings Item ...

Page 3

Characteristics Contact resistance Operate time Release time Max. operating frequency Mechanical 18,000 operations/hr Electrical Insulation resistance Dielectric withstand voltage Vibration resistance Shock resistance Life expectancy Ambient temperature Operating Ambient humidity Operating Weight Note: The values given above are initial ...

Page 4

Engineering Data ■ Maximum Switching Power MY2 AC resistive load AC inductive load (cosφ=0.4) DC resistive load DC inductive load (L/R=7 ms) Switching voltage (V) ■ Endurance MY2 (Resistive Loads) 10000 5000 3000 250 VAC 1000 30 VDC 500 30 ...

Page 5

MY4Z (Resistive Loads) 10000 5000 3000 1000 250 VAC 500 300 30 VDC 100 30 VDC 50 250 VAC 30 10 Switching Current (A) MY4Z (Inductive Loads) 10000 5000 3000 1000 30 VDC 500 300 30 VDC 100 250 VAC ...

Page 6

Dimensions Note: All units are in millimeters unless otherwise indicated. ■ 2-Pole Models MY2N ■ 4-Pole Models MY4N ■ Models with Test Button MY2IN MY4IN 264 General-purpose Relay 2.6 Eight, 1.2 dia. × 2.2 long holes 0.5 28 max. 6.4 ...

Page 7

Terminal Arrangement/Internal Connections (Bottom View) MY2 MY2N/MY2IN (AC Models) MY2N-CR/MY2IN-CR (AC Models Only) MY4(Z) MY4(Z)N/MY4(Z)IN (AC Models) MY4(Z)N-CR/MY4(Z)IN-CR (AC Models Only) MY2N/MY2IN MY2N-D2/MY2IN-D2 (DC Models) (DC Models Only) MY2N1/MY2IN1 MY2N1-D2/MY2IN1-D2 (DC Models Only) (DC Models Only) MY4(Z)N/MY4(Z)IN MY4(Z)N-D/MY4(Z)IN-D2 (DC ...

Page 8

... The values for insulation resistance were measured at 500 V at the same place as the dielectric strength. 3. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55°C. 4. When using the PYF08A-N or PYF14A operating ambient temperature exceeding 40°C, reduce the current to 60%. 5. The MY2(S) can be used at 70°C with a carry current ...

Page 9

Mounting Plates for Sockets Socket model For 1 socket PY08, PY14 PYP-1 Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets. ■ DIN Rail Track and Accessories Description Mounting rail ...

Page 10

... Dimensions Unit: mm (inch) Socket Dimensions PYF08A-E Two, 4 Eight mounting sems screws holes 72 max. 23 max. PYF14A-E Two, 4 mounting holes 72 max. 29.5 max. PY08/PY08-Y1 (See note) 42 max. Note: The PY08-Y1 includes sections indicated by dotted lines. PY08-02 16.5 max. 268 General-purpose Relay Terminal arrangement/ ...

Page 11

... Socket Dimensions PYF08A-N 22 max max. PYF-08A PYF14A PYF-14A 29.5 max. PY14/PY14-Y1 (See note) 42 max. Note: The PY14-Y1 includes sections indicated by dotted lines. PY14-02 16.5 max. Note: Use a panel with plate thickness for mounting the Sockets. Terminal arrangement/ internal connections (top view) ...

Page 12

Socket Dimensions PYF14S 31 max. 85 max. PYF08S 23.2 max. 85 max. Socket Bridge Insulating coating L 1.4 dia. conductor (See note 1.) Model number Length L (mm) PYDM-14SR 27.5±0.3 PYDM-14SB PYDM-08SR 19.7±0.3 PYDM-08SB Note: 1. The relationship between the ...

Page 13

Clip and Release Levers PYCM-14S PYF14S Lever 26.5 typ. 21.5 typ. ■ Hold-down Clips PYC-A1 PYC-A1 (2 pcs per set) (2 pcs per set) 36.3 4.5 1.2 4.5 PYC-P PYC max. 3.3 38.5 PYCM-08S PYF08S Lever 28 ...

Page 14

Mounting Plates for Back-connecting Sockets PYP-1 PYP-1 Two, 3.4-dia. holes t=1.6 PYP-18 PYP-18 72 elliptical holes ■ Mounting Track and Accessories DIN Rail Track PFP-50N/PFP-100N Note: The figure in the parentheses is for PFP-50N. PFP-100N2 End Plate PFP-M 272 ...

Page 15

Spacer PFP-S ■ Approved Standards VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435) No. of poles Coil ratings 2 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 4 6, 12, 24, 48, 100/110, 125 VDC UL Recognized (File ...

Page 16

SEV Listings (File No. 99.5 50902.01) No. of poles Coil ratings 240 VAC 6 to 125 VDC 4 Note: 1. The rated values approved by each of the safety standards (eg., UL, CSA, VDE, and SEV) may ...

Page 17

Examples of Applicable Wires (Confirmed Using Catalog Information) Type of wire Conductor type Equipment wire 2491X Flexible BS6004 Solid Switchgear BS6231 Solid Switchgear BS6231 Flexible Tri-rated control and switchgear Flexible Conduit Stranded UL1007 Flexible UL1015 Flexible UL1061 Flexible UL1430 Flexible ...

Page 18

Precautions Precautions for Connection • Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the coil spring or ...

Page 19

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 20

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords