XG4M-6431-U Omron, XG4M-6431-U Datasheet
XG4M-6431-U
Specifications of XG4M-6431-U
Related parts for XG4M-6431-U
XG4M-6431-U Summary of contents
Page 1
... XG4A PCB mount sockets are available with Long, Short or no Lock Levers. 5. Optional XG4Z-001@ side-lock levers, purchased separately, are available for use with right-angle XG4A versions that don’t include them. 6. Optional XG4Z-0002 and XG5Z-0002 top-lock levers are available for mating XG4M(-T) sockets to XG4C and XG8 plugs. ■ Ratings and Characteristics ...
Page 2
... XG4U Strain Relief with Locks) Mates with XG4 42 Flat Cable Connectors Cable Plugs: XG4E MIL Sockets: XG4M (Strain Relief: XG4S) (Strain Relief: XG4T) Polyamide resin (UL94V-0)/ Fiber-glass reinforced PBT black resin (UL94V-0)/black Phosphor bronze/nickel base, 0.15-μm gold plating (See note.) ...
Page 3
... XG4T + XG4M + XG8 (Unshrouded Plug) + XG5Z Lock Lever XG4U XG4T XG4M XG4M 18.8 XG4C XG8B XG5Z-0002 Lock Lever Flat Cable Connectors XG4T + XG4M, + XG4C + XG4Z Lock Lever XG4T XG4M 10.9 19.0 27 XG4C XG4Z-0002 Lock Lever XG4T + XG4M + XG4E 9 24.7 28.1 XG4 ...
Page 4
... XG4M-4030 XG4M-5030-U 2 (See note 4.) XG4M-5031 XG4M-6030-U 2 (See note 4.) XG4M-6031 XG4M-6430-U 2 (See note 4.) XG4M-6431-U Note: 1. Sets include the connector and strain relief. 2. With open-end cover. XG4 44 Flat Cable Connectors Mating Diagrams for XG4M-U XG4U + XG4M + XG4C XG4U 9.5 5.6 6.7 XG4C (16.8) XG4U + XG4M + XG4C 10 ...
Page 5
... Dimensions XG4M-@@30 (one polarizing guide) XG4M-@@31 (all others) Triangular mark XG4T-@@04 Strain Relief Ordering Information No. of No. of Socket+Strain Relief Set (See notes 1 and 2.) Socket with Open-end Cover (See note 3.) Strain Relief for the XG4M contacts polarity guides 10 0 XG4M-1031-T 1 XG4M-1030 XG4M-1430-T ...
Page 6
XG4E Plugs and XG4S Strain Relief Dimensions XG4E-@@31/-@@71 (With long locks) (Long locks) XG4E-@@32/-@@72 (With short locks) 0.635 × 0.635 XG4S-@@04 Strain Relief XG4 46 Flat Cable Connectors (Locking Levers on Connector) Open-end cover Strain Relief Two, 2.6 dia. ...
Page 7
... Ordering Information Use Long-lock Plugs to mate with XG4M-T Strain-relief Sockets, and use Short-lock Plugs to mate with XG4M that does not have a strain relief installed. No. of No. of Long-lock Plugs with Open-end Cov- contacts polarizing ers (See note 1.) slots 10 0 XG4E-1071 1 XG4E-1031 14 1 XG4E-1431 ...
Page 8
PCB Mount Connectors ■ XG4A Plugs with Long Lock levers Dimensions XG4A-@@31/-@@71 (With straight DIP terminals) XG4A-@@34/-@@74 (With right-angle DIP terminals) Straight DIP terminals Right-angle DIP terminals Polarity slot Polarizing Key slot Polarizing Key slot (not on models with less ...
Page 9
... Ordering Information Use in Combination with XG4M-T cable mount Sockets with strain relief or XG5M Sockets for discrete wire. No. of No. of Plugs with straight DIP terminals contacts polarizing slots 10 0 XG4A-1071 1 XG4A-1031 14 1 XG4A-1431 16 1 XG4A-1631 20 1 XG4A-2031 26 1 XG4A-2631 30 1 XG4A-3031 34 1 XG4A-3431 ...
Page 10
XG4A Plugs with Short Locks Dimensions XG4A-@@32/-@@72 (With straight DIP terminals) XG4A-@@35/-@@75 (With right-angle DIP terminals) Straight DIP terminals Right-angle DIP terminals Triangular Polarity slot mark Polarizing Key slot Polarizing Key slot (not on models with less than 14 ...
Page 11
... Ordering Information Use in Combination with XG4M cable mount Sockets without strain relief. No. of No. of Plugs with straight DIP terminals contacts polarizing slots 10 0 XG4A-1072 1 XG4A-1032 14 1 XG4A-1432 16 1 XG4A-1632 20 1 XG4A-2032 26 1 XG4A-2632 30 1 XG4A-3032 34 1 XG4A-3432 40 1 XG4A-4032 50 1 XG4A-5032 2 (See note ...
Page 12
XG4A Plugs without Lock Levers Note: XG4Z-001@ Lock Levers that can be installed after PCB assembly may be purchased separately. (See the following page.) Dimensions XG4A-@@33/-@@73 (With straight DIP terminals) XG4A-@@36/-@@76 (With right-angle DIP terminals) Straight DIP terminals Right-angle ...
Page 13
... Plug. 2. Use Long Lock Levers when mating XG4A plug to XG4M-T cable mount socket with strain relief or XG5M sockets for discrete wires. 3. Use Short Lock Levers when mating XG4A plug to XG4M without strain relief attached. Flat Cable Connectors Min. order ...
Page 14
XG4A 2-tier Plugs with Long Lock Lever Dimensions XG4A-@@39-A/-@@79-A (With long locks and right-angle DIP terminals) No. of Dimensions (mm) contacts × 2 32.0 17.5 10.16 21.8 46.4 14 × 2 37.1 22.6 ...
Page 15
... XG4A-6439-A XG4M-6430 2 (See note 3.) XG4A-6479-A XG4M-6431 Note: 1. Use with the XG4T strain relief. (XG4M-T includes the connector and strain relief as a set.) 2. Use with the XG5S Semi-cover. XG5S Hood Cover cannot be used. (See XG5 Datasheet). 3. Polarity slot pitch is 22.86 mm. Correct Use of XG4A 2-tier Plug Mounting • ...
Page 16
... XG4C-6071 64 1 XG4C-6431 2 (See note 1.) XG4C-6471 Note: 1. Polarizing slot pitch is 22.86 mm. 2. The Box-type Plug can be locked to XG4M and XG5 using the “XG4Z-0002” Lock Lever II (sold separately). XG4 56 Flat Cable Connectors Polarizing Key slot (Not on models with Polarity slot Polarizing Key slot less than 14 contacts ...
Page 17
XG4H Board-to-Board Sockets Dimensions XG4H-@@31/-@@71 (With straight DIP terminals) 6.1 3.8 Polarizing Key slot 2.45 (Not on models with Polarizing Key slot less than 14 contacts.) (Not on models with less than 10 Polarity guide Triangular contacts.) 3 mark ...
Page 18
Mating Diagrams for XG4H Plug Socket XG4H-@@31/-@@71 (With straight DIP 2.54 terminals) XG8W XG4H 2.54 Stacking XG4H-4034 (With right-angle DIP XG8W terminals) 15.23 6.82 0.52 Horizontal (forward direction) XG4 58 Flat Cable Connectors XG8W Original Plugs (See XG8 Datasheet) ...
Page 19
... XG4A-143@ XG4E-103@ XG4E-143@ — XG4C-103@ XG4C-143@ — Flat Cable Connectors contacts XG4M-1630 to XG4M-6430 Polarizing Key slot XG4M-5031, XG4M-6031, XG4M-6431 Polarizing guide XG4A-163@ to XG4A-643@ Polarizing Key slot XG4E-163@ to XG4E-643@ XG4A-507@, XG4A-607@, XG4A-647@ Polarizing slot XG4E-507@, XG4E-607@, XG4E-647@ XG4C-163@ to XG4C-643@ Polarizing slot XG4C-507@, XG4C-607@, XG4C-647@ ...
Page 20
... Install the XG4Z-0004 polarizing key on XG4A, XG4E and XG4C plugs that do not have a polarizing slot, to prevent reverse connec- tion with XG4M cable sockets that do not have a polarizing guide. For all other versions, the molded polarity guides and slots can be used by themselves to help prevent reverse insertion. However, use the polarizing key with these versions as well for best results ...
Page 21
MEMO XG4 Flat Cable Connectors ...
Page 22
... All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B ...