Z-15GQ Omron, Z-15GQ Datasheet - Page 19

no-image

Z-15GQ

Manufacturer Part Number
Z-15GQ
Description
BASIC SWITCH
Manufacturer
Omron
Series
Zr
Datasheets

Specifications of Z-15GQ

Microswitch Type
Standard
Actuator Style
Plunger
Operating Force Max
350gf
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Current Max
15A
Switch Terminals
Screw
Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
15A @ 125VAC
Actuator Type
Overtravel Plunger
Mounting Type
Panel Mount
Termination Style
Solder Lug
Operating Force
350gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Z15GQ

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z-15GQ-B
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
Z-15GQ21-B
Manufacturer:
OTAX
Quantity:
450
Part Number:
Z-15GQ2155-B
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
Z-15GQ22
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
Z-15GQ22-B
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
Z-15GQ55-B
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
Z-15GQA55-B5V
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number.
Flexible Rod (Coil Spring)
Z-15GNJ55-B
Flexible Rod (Steel Wire)
Z-15HNJS55-B
2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions.
(111.3)
(130.1)
100
(13.6)
(13.8)
43.4
16.3
16.3
38
± 0.4
4.2
4.2
(22)
+0.075
+0.075
-0.025
-0.025
PT
PT
4.36
4.36
25.4
25.4
49.2
49.2
23.3
23.3
+0.1
+0.1
-0.05
-0.05
30 Operating range *2
30 Operating range *2
± 0.1
± 0.1
Four, M3 set screws
with hexagonal holes
± 0.25
± 0.25
Rubber cap
Rubber cap
dia.
dia.
11.9
11.9
4.2
4.2
+0.075
+0.075
-0.025
-0.025
dia. hole
dia. hole
1-dia. stainless
steel wire *3
Nylon rod
12 dia.
12 dia.
9.2
9.2
6.1 dia.
3.2 dia.
17.45
17.45
*1
*1
General-purpose Basic Switch
± 0.2
± 0.2
*1. Operation is possible in any direction other than the
*2. Use only the area within the top 30 mm of the rod as
*1. Operation is possible in any direction other than the axial
*2. Use only the area within the top 30 mm of the rod as the
*3. The steel wire can be replaced if damaged.
axial direction (indicated by the arrow
the operating part. (Do not use the area that falls within
80 mm from the mounting hole as the operating part.
Using this area may cause damage to the nylon rod.
direction (indicated by the arrow
operating part. (Do not use the area that falls within 100
mm from the mounting hole as the operating part.
Using this area may cause damage to the steel wire.)
(Model: Lever for HNJS55)
OF max.
PT max.
OF max.
PT max.
TT max.
).
).
Z
(25 mm)
(20 mm)
40 mm
15 gf
50 gf
165

Related parts for Z-15GQ