M2 TEMP CONV TC J 0-300 C

88950154

Manufacturer Part Number
88950154
Description
M2 TEMP CONV TC J 0-300 C
Manufacturer
Crouzet USA
Type
Converterr
Datasheets

Specifications of 88950154

Accessory Type
Temperature Converter
Brand/series
Millenium 3
Primary Type
Option
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
Millenium II+
For Use With
966-1006 - IO EXPAND XR14 24V - MILLENIUM 3646-1121 - IO EXPAND XR10 120V - MILLENIUM3646-1120 - IO EXPAND XR10 24V - MILLENIUM 3646-1119 - IO EXPAND XR06 120V - MILLENIUM3646-1118 - IO EXPAND XR06 24V - MILLENIUM 3646-1117 - CONTROL LOGIC XD26 120VAC DIN MT646-1116 - CONTROL LOGIC XD26 24VDC DIN MT646-1115 - CONTROL LOGIC XD10 120VAC DIN MT646-1114 - CONTROL LOGIC XD10 24VDC DIN MT646-1101 - CONTRL LOGIC 12I/O 120VAC DIN MT646-1100 - CONTROL LOGIC 12I/O 24VDC DIN MT646-1099 - CONTROL LOGIC 8I/O 12VDC DIN MNT646-1098 - CONTROL LOGIC 8I/O 24VAC DIN MNT646-1097 - CONTROL LOGIC 8I/O 120V DIN MNT646-1096 - CONTROL LOGIC 8I/O 24VDC SSR646-1095 - CONTROL LOGIC 8I/O 24VDC DIN MNT646-1094 - CONTROL LOGIC 12I/O 120V DIN MNT646-1093 - CONTROL LOGIC 12I/O 24VDC DIN MT646-1092 - CONTROL LOGIC 8I/O 120V DIN MNT646-1091 - CONTROL LOGIC 8I/O 24VDC DIN MNT
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
646-1083
www.millenium3.crouzet.com
For adapted products, see page page 64-65
Characteristics of analogue extension 88970241
General characteristics of analogue extension 88970241
See page 22, except:
Certifications
Earthing
Analogue inputs
Inputs used as analogue inputs
Input
Input range
Input impedance
Maximum non destructive current/voltage
Value of LSB
Input type
Resolution
Conversion time
Accuracy at 25°C
Accuracy at 55°C
Isolation between analogue channel and power
supply
Longueur câble
Protection against polarity inversions
Analogue outputs
Range output
Input type
Max. load
Value of LSB
Resolution
Conversion time
Accuracy at 25°C
Accuracy at 55°C
Repeat accuracy at 55 °C
Isolation between analogue channel and power
supply
Cable length
Protection against polarity inversions
PWM
Range output
Max. load
PWM cyclic ratio
Frequency
Accuracy
Built-in protections
Dimensions (mm)
XA04
Input / Output Connections
See Page 40-43 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download"
25
35,5
57,4
70
0-10 V
IP and IQ
0
≥ 18 kΩ
30 V
9.8 mV
Common mode
10 bits
Module cycle time
± 1%
± 1%
None
10 m maximum, with shielded
cable (sensor not isolated)
Command ignored
0
Resistive
10 mA
10 mV
10 bits
Controller cycle time
±1% of full scale
±1% of full scale
± 1%
None
10 metres maximum, with shielded cable (sensor not isolated)
Yes
V power supply
≥ 1.2 kΩ (I ≤ 20 mA)
1024 steps
78 Hz, 312.5 Hz, 666.6 Hz, 1000 Hz, 1250 Hz, 1428 Hz, 1666 Hz, 2000 Hz
1% across the entire temperature range for PWM ratios from 5% to 95%
Against overvoltages: Yes
UL, CSA
GL (pending)
Yes, refer to the quick reference guide supplied with the product
10 V
10 V
0-20 mA
IP and IQ
0
246 Ω
30 mA
20 μA
Common mode
10 bits
Module cycle time
± 1%
± 1%
None
10 m maximum, with shielded
cable (sensor not isolated)
Command ignored
20 mA
Pt 100
IQ
-25
-
-
0.15°C
Pt 100 probe - IEC 751 - 3-wire
10 bits
Module cycle time
±1.5°C
±1.5°C
None
10 m maximum, with shielded
cable (sensor not isolated)
Command ignored
125°C
37