Temperature Control
Thermocouples
Reference junction drift
Input Impedance
Calibration
RTD
Line Resistance
Input types and standard range
Input types
TC L
TC L
TC J
TC J
TC K
TC K
TC N
TC R
TC S
RTD Pt100
RTD Pt100
Decimal Point
Ordering Information
Inputs
Reference Junction
Configurable
mA & V inputs
Measurement Range
Type
Output
Relay
Logic
Relay
Logic
Heating and/or cooling function
2 independent alarms
Load break detection
2nd setpoint which can be selected remotely
Manual/automatic power adjustment
RS 485 / MODBUS - JBUS serial communication
option
Example: 89 422 008, MIC 48 temperature controller
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865/ www.crouzet-usa.com
adjustable 0000, 000.0,
Standard products, stocked
Standard products, non stock
J, K, R, S, & N
L
3 wire PT 100
Temp Scale in
0 / 400.0 C
0 / 900 C
0 / 400.0 C
0 / 1000 C
0 / 400.0 C
0 / 1200
0 / 1400 C
0 / 1760 C
0 / 1760 C
-199.9 / 400.0 C
-200 / 800.0 C
Input
0 –20mA
4 – 20mA
0 – 60mV
12 - 60mV
0 – 5V
1 – 5V
0 – 10V
2 – 10V
Automatic cold junction
compensation 0-50 C
C
-199.9 / 400.0 F
-330 / 1470 F
Impedance
< 5
> 1M
> 200K
> 400K
-1999 to +4000
Conforms to IEC 584-1
Conforms to Din 43710
0.1 C / C
Conforms to IEC 584-1
20
Temp Scale in F
0 / 1650 F
0 / 1830 F
0 / 2190 F
0 / 2500 F
0 / 3200 F
0 / 3200 F
1M
00.00,
Max
Products and specifications subject to change without notice.
Consult factory for application assistance.
0.000
100 – 240 Vac
24Vac / Vdc
100 – 240 Vac
24Vac / Vdc
Input Power
Output element
Main output cycle time
Cool output or alarm 1 output
OUT3
Alarm 2 output
Manual adjustment of the
output power
Outputs
Output Type
Action type
Power output
limit :
SOFT-START
Note : this function is only active on starting if the measurement is
less than the setpoint.
OUT1
Main
Output
OUT2
Load break output and/or
Automatic/manual mode
It is possible to force the heat or cool output power by pressing the
key
Disabling the power status
It is possible to disable the power output. In this case, the
controller operates as a simple temperature display unit. This
option is frequently used during machine adjustment.
General Specifications
Power Supply
Frequency
Tolerance
Power consumption
Display
on the front panel.
Measurement
Setpoint
discontinuous
logic
can be programmed for heating and/or cooling
heating action
heating/cooling
N/O contact
action
Part Number
Without RS 485 link
(N/C contact is possible via a jumper)
89 422 008
89 422 018
89 422 002
89 422 012
Level 0: < 0.5 V
Level 1: 14 V
1 s to 99 s
N/O -2A contact, 250 V
N/O -2A contact, 250 V
Heat
Cool
100 – 240 Vac , 24Vac / Vdc
50 / 60 Hz
-15% / +10% Vin
8VA max
4 digits, Red LED’s, 7 segment,
10mm height
4 digits, Green LED’s, 7 segment,
7.5mm height
3A 250 Va resistive
24 V
adjustable from 0 to 100%
adjustable from -100
to +100 %
MIC 48
±20% @ 20 mA max
±20% @ 1 mA max
Part Number
With RS 485 link
89 422 408
89 422 418
89 422 402
89 422 412
0 to 99 %
0 to 99 %
MIC 48
~
~
resistive
resistive