Key features of the GT5Y series include:
Specifi cations
Rated Operating Voltage
Contact Form
Rated Load
Allowable Contact Power
Allowable Voltage
Allowable Current
Temperature Error
Setting Error
Reset Time
Insulation Resistance
Dielectric Strength
Vibration Resistance
Shock Resistance
Power Consumption
Electrical Life
Mechanical Life
Operating Temperature
Operating Humidity
4PDT, 3A or DPDT, 5A contacts
4 time ranges
Repeat error ±0.2% maximum
Control settings by hand or screwdriver
Power ON and timing out LED indicators
Uses the same sockets and hold-down clips as IDEC’s RY4S and RU series relays
1. Minimum applicable load: GT5Y-2: 5V DC, 20mA (reference value); GT5Y-4: 5V DC, 10mA (reference value).
2. Inductive load: cos ø =0.3, L/R=7msec.
Resistive Load
Inductive Load
Resistive Load
Inductive Load
Cos ø = 0.3
L/R = 7msec
UL, c-UL Listed
File No. E55996
GT5Y Series — ON Delay Timers
500,000 operations minimum
USA: 800-262-IDEC
2,000V AC, 1 minute (except between contacts of the same pole)
±3% maximum (over –10 to 50°C, reference temperature 20°C)
(220V AC, 5A)
30V DC, 2.5A
When turning power off after time up: 0.1 second maximum
When turning power off before time up: 1 second maximum
220V AC, 5A
220V AC, 2A
30V DC, 5A
1100VA AC
440VA AC
150W DC
75W DC
GT5Y-2
DPDT
5A
Operating extremes: 100N (approximate 10G)
Damage limits: 500N (approximate 50G)
50,000,000 operations minimum
100V AC type: 1.5VA (at 50Hz)
200V AC type: 1.6VA (at 50Hz)
100 to 120V AC (50/60Hz)
200 to 240V AC (50/60Hz)
100N (approximate 10G)
24V DC type: 0.9W
250V AC, 125V DC
100MΩ minimum
±10% maximum
45 to 85% RH
–10 to +50°C
24V DC
24V AC
12V DC
Canada: 888-317-IDEC
200,000 operations minimum
220V AC, 0.8A
(110V AC, 3A)
30V DC, 1.5A
220V AC, 3A
30V DC, 3A
660VA AC
176VA AC
90W DC
45W DC
GT5Y-4
4PDT
3A
GT5Y Series
853