Manufacturer Part Number
HC4-HL-AC240V
Description
HC4 Relay (Plug-in W/ LED)
Manufacturer
PANASONIC EW
Datasheet
ORDERING INFORMATION
Contact arrangement
1:
2:
3:
4:
4D:
Terminal arrangement
H:
HL:
HP:
HPL:
HTM:
Coil voltage
AC
DC
Contact material
Contact arrangement
Notes: UL/CSA approved type is standard.
http://www.mew.co.jp/ac/e/environment/
RoHS Directive compatibility information
6, 12, 24, 48, 100 (100/110), 120 (110/120), 200 (200/220), 240 (220/240) V
6, 12, 24, 48, 100 (100/110) V
1 Form C
2 Form C
3 Form C
4 Form C
Bifurcated contact (twin)
Plug-in type
Plug-in type
Plug-in with LED indication
PC board type
PC board with LED indication
TM type
Please inquire about VDE (1 Form C, 2 Form C, and 4 Form C only) and TV-3 (1 Form C and 2 Form C only) approved products.
Bifurcated contact (twin)
1 Form C
2 Form C
3 Form C
4 Form C
TM type
Contact material
PC board type
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
(cadmium-free)
Ag alloy
FEATURES
1. Long track record means reliable
quality.
2. Can provide switching across the
range from low to high level power
loads (100 A to 10 A).
3. Full range of types
Standard types include 1 Form C,
2 Form C, 3 Form C, 4 Form C, 4-pole
bifurcated (twin), plug-in type, PC board
type, and TM type.
4. HC relay with LED indication type
also available
5. UL, CSA approval is standard
Compliance also with Japanese
Electrical Appliance and Material Control
Law.
TYPICAL APPLICATIONS
Suitable for factory automation
equipment and automotive devices
1. Control panels, power supply
equipment, molding equipment,
machine tools, welding equipment,
agricultural equipment, etc.
F
F
F
MINIATURE RELAY FOR
WIDER APPLICATIONS
HC
AgNi type
Nil
Nil
2. Office equipment, automatic
vending machines,
telecommunications equipment,
disaster prevention equipment,
copiers, measuring devices, medical
equipment, amusement devices, etc.
3. All types of household appliance
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances. (The suffix “F”
should be added to the part number. The
Suffix “F” is required only for 1 Form C,
2 Form C, 3 Form C contact type. The
4 Form C and 4 Form C bifurcated (twin)
contact type is originally cadmium-free,
the suffix “F” is not required.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
HC RELAYS
HC
1c, 2c, 4c
VDE

Related parts for HC4-HL-AC240V

HC4-HL-AC240V Summary of contents

Page 1

Plug-in type PC board type TM type RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ ORDERING INFORMATION Contact arrangement 1: 1 Form Form Form Form C 4D: Bifurcated contact (twin) Terminal arrangement H: Plug-in ...

Page 2

... HC4-H-DC100V HC4D-H-DC100V 4 Form C 4 Form C (twin) Part No. Part No. HC4-HL-AC6V HC4D-HL-AC6V HC4-HL-AC12V HC4D-HL-AC12V HC4-HL-AC24V HC4D-HL-AC24V HC4-HL-AC100V HC4D-HL-AC100V HC4-HL-AC120V HC4D-HL-AC120V HC4-HL-AC200V HC4D-HL-AC200V HC4-HL-AC240V HC4D-HL-AC240V HC4-HL-DC6V HC4D-HL-DC6V HC4-HL-DC12V HC4D-HL-DC12V HC4-HL-DC24V HC4D-HL-DC24V HC4-HL-DC48V HC4D-HL-DC48V HC4-HL-DC100V HC4D-HL-DC100V 4 Form C 4 Form C (twin) Part No. Part No. HC4-HP-AC6V HC4D-HP-AC6V HC4-HP-AC12V ...

Page 3

... HC4D-HPL-DC12V HC4-HPL-DC24V HC4D-HPL-DC24V HC4-HPL-DC48V HC4D-HPL-DC48V HC4-HPL-DC100V HC4D-HPL-DC100V 4 Form C 4 Form C (twin) Part No. HC4-HTM-AC6V HC4D-HTM-AC6V HC4-HTM-AC12V HC4D-HTM-AC12V HC4-HTM-AC24V HC4D-HTM-AC24V HC4-HTM-AC48V HC4D-HTM-AC48V HC4-HTM-AC100V HC4D-HTM-AC100V HC4-HTM-AC120V HC4D-HTM-AC120V HC4-HTM-AC200V HC4D-HTM-AC200V HC4-HTM-DC6V HC4D-HTM-DC6V HC4-HTM-DC12V HC4D-HTM-DC12V HC4-HTM-DC24V HC4D-HTM-DC24V HC4-HTM-DC48V HC4D-HTM-DC48V HC4-HTM-DC100V HC4D-HTM-DC100V Nominal operating Coil inductance power N ...

Page 4

HC 2. Specifications Characteristics Item Arrangement Contact pressure Contact Initial contact resistance, max Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Rating Max. switching current Nominal operating power Min. switching capacity (Reference value)* ...

Page 5

... Coil applied voltage, %V All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 2.-(1) Switching capacity range (single contact type) 250 100 HC4c HC2c HC1c 1mA 10mA 1A 5A 10A 7A AC current 3.-(2) Coil temperature rise (2 Form C, AC type) ...

Page 6

HC DIMENSIONS (Unit: mm inch) 1. Plug-in type 1 Form C type External dimensions 20.8 .819 27.2 1.7 1.7 0.6 1.071 .067 .067 .024 35.2 1.386 1 .039 6.4 .252 2.54 0.5 .100 .020 13.35 .526 4.45 4.41 .175 .174 ...

Page 7

Form C and 4-pole bifurcated (twin) types 2. PC board type PC board pattern 1 Form C 2 Form C 4.1 4.1 .161 .161 10.4 10.4 .409 .409 16.8 16.8 .661 .661 4.45 8-2 dia. hole 5-2 dia. hole ...

Page 8

type Chassis (Panel) cutout 2-3.6 dia. 2-.142 dia. 37.6 1.480 Tolerance: 0.1 Schematic Same schematic as plug-in type HC relay Be aware that there is no LED indicator with CR circuit and built-in diode types. For Cautions ...

Page 9

... PC board PC board HC3-socket for 3-pole PC board 1/2/4-pole HC4-socket for (common) PC board HC4-wrapping socket 1/2/4-pole Wrapping (common) HC4-wrapping socket (spring) Notes: 1. Use the retainer that is shipped with the terminal socket. 2. UL/CSA approved type is standard (except for wrapping socket). ACCESSORIES (Sockets and Terminal sockets) 4 ...

Page 10

... Notes: 1. Use the retainer that is shipped with the terminal socket. 2. UL/CSA approved type is standard (except for HC4-TSF-K order to prevent breakage and disfiguring, the screw tightening torque for the terminal socket should be within the range of 0.49 to 0.69 N· 7kgf·cm}. ...

Page 11

... HC2-Socket (HC2-SS-K) 4.45 4.45 .175 .175 4.45 .175 7.06 .278 1.27 .050 25.5 1.004 21.2 7.65 .835 General tolerance: 0.3 .301 HC4-Socket (HC4-SS-K) 25.5 1.004 4.06 13.35 .160 .526 9.14 .360 10.41 16.76 .410 .660 21.2 .835 7.65 General tolerance: 0.3 .301 Side-by-side installation 25 ...

Page 12

... All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. HC2- PC board type socket (HC2-PS-K) 4.45 4.45 .175 .175 4.45 .175 7.06 .278 21.2 .835 General tolerance: 0.3 HC4- PC board type socket (HC4-PS-K) 4.06 13.35 .160 .526 9.14 .360 10.41 .410 16.76 .660 21.2 .835 General tolerance: 0 ...

Page 13

... Note: The external and mounting dimensions are the same for 1-pole (HC1-WS-K), 2-pole (HC2-WS-K), and 3-pole (HC3-WS-K) types. Only the number of terminals varies. Wrapping type sockets with hold-down clip (HC4-WS) 5 .197 Mounting hole diagram External dimensions 25.5 1.004 13 ...

Page 14

... HC2-Slim type terminal sockets for DIN rail assembly (HC2-SFD-S) HC2-high terminal socket for DIN rail assembly (HC2-SFD-K) HC3-high terminal socket for DIN rail assembly (HC3-SFD-K) HC4-high terminal socket for DIN rail assembly (HC4-SFD-K) All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. External dimensions 15 0 ...

Page 15

... HC RELAY ACCESSORIES HC vertical type terminal socket (HC4-TSF-K) Mounting hole diagram HC2-Slim type HC2, HC3 and HC4 9 .354 15 0.2 15 0.2 26 1.024 .591 .008 .591 .008 2-M3.5 screw hole 67 (or 4.2 0.1 dia. hole) 2.638 2-M.138 screw hole 57 0.5 (or .165 .004 dia. hole) 2 ...

Page 16

... HC4-high terminal socket (HC4-HSF-K) suitable for and 4 Mounting hole diagram HC2-SF-K 2-M3.5 screw hole (or 4.2 0.1 dia. hole) 2-M.138 screw hole (or .165 .004 dia. hole) .906 .472 .472 40 1.575 30 30 1.181 1.181 5 .197 Panel hole dimensions for side-by-side mounting All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. ...

Page 17

MOUNTING RAIL AND FASTENING PLATE DIMENSIONS (Unit: mm inch) Mounting rail ATA48011 1,000 39.37 5.5 .217 2.75R 5 .591 .394 .591 2.75R .591 .394 .197 40-5.5 15 over hole 40-.217 .591 RoHS Directive compatibility information ...