HS5B-02ZB IDEC, HS5B-02ZB Datasheet - Page 3

no-image

HS5B-02ZB

Manufacturer Part Number
HS5B-02ZB
Description
Safety Swtich 2NC Metal Head
Manufacturer
IDEC
Datasheet
352
HS5B-11 (1NO-1NC)
Plastic Head - using the straight actuator (HS9Z-A51)
RP: Actuator Mounting Reference Position
Door/
Switch
Status
Door
Circuit
Diagram
Main
Circuit
Aux.
Circuit
Slot Plug (supplied)
(Note)
1. Main Circuit: used to enable the machine to start only when the main circuit is closed.
2. Auxiliary Circuit: used to indicate whether the machine circuit or door is open or closed.
Plug the unused actuator insertion slot using the slot plug supplied with the interlock switch.
Door Closed
Machine ready to operate
Actuator Stop
Actuator
3-4: Closed
6.2
1-2: Open
26.4
Status 1
HS5B Series
-
+
RP
1
2
3
4
42.2
5.2
36.2
Plastic Head (black or gray)
91
Door opened
Machine cannot be started
Application Examples and Circuit Diagrams
Conduit Port
1-2: Closed
3-4: Open
Status 2
-
+
1
2
3
4
Dimensions (mm)
www.idec.com
2-M4 Screws
Mounting Hole Layout
36
5.2
20 to 22
RP
HS5B-02 (2NC)
26.4
Door/
Switch
Status
Door
Circuit
Diagram
Main
Circuit
Aux.
Circuit
Actuator Stop
6.2
Actuator
Door Closed
Machine ready to operate
36.2
3-4: Closed
1-2: Closed
6±1
Status 1
-
+
1
2
3
4
Plastic Head (black or gray)
91
Door Interlock Switches
Conduit Port
Door opened
Machine cannot be started
3-4: Open
1-2: Open
Status 2
-
+
1
2
3
4

Related parts for HS5B-02ZB