LK1AF-24V PANASONIC EW, LK1AF-24V Datasheet

no-image

LK1AF-24V

Manufacturer Part Number
LK1AF-24V
Description
LK Relay
Manufacturer
PANASONIC EW
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LK1AF-24V
Manufacturer:
PANASONIC
Quantity:
12 000
LK
FEATURES
1. High inrush current capability
1) Operating load capability:
2) UL/CSA, TV-5
SPECIFICATIONS
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
*
TYPICAL APPLICATIONS
• AV equipment: TV’s, VTR’s, etc.
• OA equipment
• HA equipment
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive
load)
Expected
life (min.
ope.)
Nominal operating power
1
2
3
4
5
6
7
8
RoHS Directive compatibility information
Measurement at same location as “Initial breakdown voltage” section.
Detection current: 10mA
Wave is standard shock voltage of 1.2
Excluding contact bounce time.
Half-wave pulse of sine wave: 11 ms; detection time: 10 s
Half-wave pulse of sine wave: 6 ms
Detection time: 10 s
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
inrush 100 A, steady 5 A
and desired reliability level, therefore it is recommended to check this with the
actual load.
http://www.nais-e.com/
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity
(Reference value)
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
(at rated load)
24.0
.945
11.0
.433
25.0
.984
mm
#1
inch
50 s according to JEC-212-1981
5 A 277 V AC, 5 A 30 V DC
277 V AC, 30 V DC
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
5A (AC), 5 A (DC)
1,385 VA, 150 W
100 mA, 5 V DC
Max. 100 m
AgSnO
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm
inch
2) Surge withstand voltage between
contact and coil: 10,000 V or more
3. High noise immunity realized by the
card separation structure between
contact and coil
4. Popular terminal pitch in AV
equipment field
ORDERING INFORMATION
1 Form A
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.
(Note) Standard packing Carton: 100 pcs. Case: 500 pcs.
530 mW
2
Coil
10
CURRENT CAPABILITY
Contact arrangement
10
(In compliance with IEC65)
2
5
SLIM POWER RELAY
WITH HIGH INRUSH
type
6
COM
1a: 1 Form A
Ex.
N.O.
Characteristics
Max. operating speed
Initial insulation resistance*
Initial
breakdown
voltage*
Initial surge voltage between contact
and coil*
Operate time*
Release time (without diode)*
(at nominal voltage)
Temperature rise (at 70 C)
Shock
resistance
Vibration
resistance
Conditions for operation,
transport and storage*
(Not freezing and condens-
ing at low temperature)
Unit weight
LK
16.5
.650
.787
20
2
3
Protective construction
1a
F: Flux-resistant type
mm
.039
.039
Between open contacts
Between contacts and
coil
Functional*
Destructive*
Functional*
Destructive
4
.236
1
1
(at nominal voltage)
.295
inch
7.5
8
F
Ambient temp.
Humidity
Air pressure
5. Space-saving slim type
Base area: Width 11
6. Conforms to the various safety
standards
UL, CSA, VDE, TÜV, SEMKO, SEV, BSI
approved
5
7
6
1
LK RELAYS
4
Width .433
at double amplitude of 1.5 mm
at double amplitude of 1.5 mm
voltage at 5A contact carrying
Min. 1,000 M
–40 to +70 C
Max. 35 C with nominal coil
current (resistance method)
Max. 15 ms (at 20 C
Max. 5 ms (at 20 C
24V
5, 6, 9, 12, 18, 24 V
Creepage distance and clear-
ances in compliance with IEC65
1,000 Vrms for 1 min
4,000 Vrms for 1 min
Approx. 12 g
Coil voltage (DC)
VDE
86 to 106 kPa
5 to 85%R.H.
10 to 55 Hz
10 to 55 Hz
1,000 m/s
Length 24 mm
10,000 V
200 m/s
20 cpm
Length .945 inch
Card
Partition wall
–40 to +158 F
(at 500 V DC)
2
.42 oz
2
68
68
F)
F)

Related parts for LK1AF-24V

LK1AF-24V Summary of contents

Page 1

LK 11.0 .433 24.0 .945 25.0 .984 mm inch RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. High inrush current capability 1) Operating load capability: inrush 100 A, steady UL/CSA, TV-5 SPECIFICATIONS Contact Arrangement Initial contact resistance, max. ...

Page 2

... Part No. voltage (max (Initial) LK1aF-5V 5 3.5 LK1aF-6V 6 4.2 LK1aF-9V 9 6.3 LK1aF-12V 12 8.4 LK1aF-18V 18 12.6 LK1aF-24V 24 16.8 DIMENSIONS Dimension : General tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012 REFERENCE DATA 1 ...

Page 3

... Mis- AC277V contacting DC12V detection circuit 6-2. Electrical life test (UL lamp load test TV-5) Tested sample: LK1aF-12V, 6 pcs. • Overload test Load: 7.5 A 120 V AC (60 Hz), Inrush: 111 A Operation frequency: 10 times/min (ON: OFF = No. of operations: 50 ope. • Endurance test Load: 5A 120 V AC (60 Hz), ...

Related keywords