SPECIFICATIONS
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
*
TYPICAL APPLICATIONS
• Audio visual equipment
• Office equipment
• Home appliances
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive
load)
Expected life
(min.
operations)
Nominal operating power
1
2
3
4
5
6
7
8
RoHS Directive compatibility information
TVs, VTRs
LBP, CRT
Refrigerator, Air conditioner
Measurement at same location as “Initial breakdown voltage” section.
Detection current: 10mA
Wave is standard shock voltage of 1.2
Excluding contact bounce time.
Half-wave pulse of sine wave: 11 ms; detection time: 10 s
Half-wave pulse of sine wave: 6 ms
Detection time: 10 s
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
and desired reliability level, therefore it is recommended to check this with the
actual load.
http://www.nais-e.com/
24.0
.945
Nominal switching
capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity
(Reference value)
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
(at rated load)
11.0
.433
25.0
.984
mm
50 s according to JEC-212-1981
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
#1
inch
10 A 277 V AC, 5 A 30V DC
277 V AC, 30 V DC
10 A (AC), 5A (DC)
2,770 V A, 150W
100 mA, 5 V DC
Max. 100 m
AgSnO
FEATURES
1. High switching capacity: 10 A 277V
AC
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm
inch
2) Surge withstand voltage between
contact and coil: 10,000 V or more
3. High noise immunity realized by the
card separation structure between
contact and coil
ORDERING INFORMATION
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.
Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
1 Form A
530 mW
2
10
Contact arrangement
(In compliance with IEC65)
SLIM POWER RELAY
10
2
5
2. 5 V, 9 V, 18 V DC types are also available. Please consult us for details.
type
6
1a: 1 Form A
Ex. LKP
10 A
Characteristics
Max. operating speed
Initial insulation resistance*
Initial *
breakdown
voltage
Initial surge voltage between contact
and coil*
Operate time*
Release time (without diode)*
(at nominal voltage)
Temperature rise (at 70 C)
Shock resistance
Vibration resistance
Conditions for operation,
transport and storage*
(Not freezing and
condensing at low
temperature)
Unit weight
1a
2
3
Protective construction
F: Flux-resistant type
Between open
contacts
Between contact and
coil
4
.236
(at nominal voltage)
F
8
Functional*
Destructive*
Functional*
Destructive
4. Popular terminal pitch in AV
equipment field
5. Space-saving slim type
Base area: Width 11
6. Conforms to the various safety
standards
UL/CSA, VDE, TÜV and SEMKO, SEV
approved
LK-P RELAYS
1
Ambient
temp.
Humidity
Air
pressure
4
–
5
7
6
12V
Width .433
at double amplitude of 1.5mm
at double amplitude of 1.5mm
Min. 1,000 M
Max. 45 C with nominal coil
voltage and at 10 A contact
Max. 15 ms (at 20 C
1,000 m/s
Max. 5 ms (at 20 C
200 m/s
5, 6, 9, 12, 18, 24V
20 cpm (at rated load)
1,000 Vrms for 1 min.
4,000 Vrms for 1 min.
(resistance method)
Coil voltage(DC)
Approx. 12 g
VDE
–40 F to +158 F
carrying current
–40 C to +70 C
5 to 85% R.H.
86 to 106 kPa
10 to 55Hz
10 to 55Hz
10,000 V
Length 24 mm
2
2
{approx. 20 G}
{approx. 100 G}
Length .945 inch
(at 500 V DC)
.42 oz
LK-P
68
68
F)
F)