SX150GSMT Honeywell Sensing and Control, SX150GSMT Datasheet - Page 2

ASG/SENSYM

SX150GSMT

Manufacturer Part Number
SX150GSMT
Description
ASG/SENSYM
Manufacturer
Honeywell Sensing and Control
Series
SXr
Datasheet

Specifications of SX150GSMT

Pressure Type
Gauge
Operating Pressure
150 PSI
Port Size
Male, 0.09" (2.28mm) Tube
Output
75 ~ 110mV
Voltage - Supply
12V
Termination Style
PCB
Operating Temperature
-40°C ~ 85°C
Package / Case
8-SMD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-3110
SX SMT Series
SPECIFICATIONS
Characteristic
Supply voltage
Operating temperature
Storage temperature
Lead temperature (soldering 2 s to 4 s)
STANDARD PRESSURE RANGES FOR SX SERIES
PERFORMANCE SPECIFICATIONS
Characteristic
Temperature coefficient of span
Zero pressure offset T
Temperature coefficient of offset
Combined, linearity and hysteresis
Long term stability of offset and sensitivity
Response time (10% to 90%)
Input resistance T
Temperature coefficient of resistance
Output impedance
Repeatability
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Difference in output at any pressure with the operating pressure range and temperature within 0 °C to 70 °C [32 °F to 158 °F]
2
Operating Pressure
0 psi to 100 psi
0 psi to 150 psi
Reference Conditions: Supply voltage, Vs = 5.0 Vdc, T
0 psig, pressure applied to P1 unless otherwise noted.
If maximum pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may
fracture.
Sensitivity is the ratio of the output signal voltage change to the corresponding input pressure change. The sensitivity is
characterized by design and periodic production testing. This parameter in not 100 % tested in production.
This is the best straight line fit for operation between 0 °C to 70 °C [32 °F to 158 °F]. For operation outside this temperature,
contact Honeywell representative for more specific application information.
This parameter is not 100 % tested. It is guaranteed by process design and tested on a sample basis only. Temperature
coefficient of span for the 1.0 psi and 5.0 psi devices is -2550 ppm/°C to -2050 ppm/°C.
Slope of the best straight line fit for operation between 0 °C to 70 °C [32 °F to 158 °F]. For operation outside this temperature,
contact factory for more specific application information.
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing
pressure.
Long-term stability over a one year period.
Response time for 0 psi to full scale span pressure step change.
after 100 temperature cycles 0 °C to 70 °C [32 °F to 158 °F], 1.0 million pressure cycles 0 psi to full-scale span.
0 psi to 15 psi
0 psi to 30 psi
0 psi to 1 psi
0 psi to 5 psi
www.honeywell.com/sensing
(10)
A
= 25 °C [77 °F]
(1)
A
Maximum Pressure
(9)
(4,5)
(6,5)
(7)
150 psi
200 psi
20 psi
20 psi
30 psi
60 psi
(4,5)
(1)
(8)
(2)
Maximum Rating
12 Vdc
-40 °C to 125 °C [-40 °F to 257 °F]
-55 °C to 125 °C [-67 °F to 257 °F]
250 °C [482 °F]
-2400
A
-35.0
Min.
(1)
Nominal
= 0 °C to 70 °C [32 °F to 158 °F], common-mode line pressure =
3.90
2.70
1.50
0.66
0.30
0.14
Sensitivity
-2150
-20.0
Typ.
100
750
0.2
0.1
4.1
4.1
0.5
4
(3)
Std. Dev.
±0.40
±0.38
±0.25
±0.06
±0.05
±0.02
-1900
Max.
810
0.5
0
mV/V/psi
mV/V/psi
mV/V/psi
mV/V/psi
mV/V/psi
mV/V/psi
Unit
µV/V/°C
ppm/°C
ppm/°C
% FSS
% FS
Unit
mV
mV
µs