W91-A152-40 Tyco Electronics, W91-A152-40 Datasheet - Page 3

no-image

W91-A152-40

Manufacturer Part Number
W91-A152-40
Description
W91-A152-40=M6/M7/M9/W6/W7
Manufacturer
Tyco Electronics
Datasheet
Ordering Information
W6 Series
Authorized distributors are more likely to stock the following items.
1. Circuit Breaker Mounting:
2. Number of Poles:
3. Circuit Function: (Only X is VDE approved)
4. Actuator:
5. Termination:
6. Maximum Line Voltage: (See Table 1 for current ranges)
7. Time Delay Curve:
8. Amp Rating:
9. Agency Approval:
W67-A2Q12-5
W67-A2Q12-10
W67-X2Q10-3
W67-X2Q10-5
W67-X2Q12-2
W67-X2Q12-3
Issued 11-08
www.tycoelectronics.com
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
67 = Single pole
A = Series trip with auxiliary switch (.093” QC)
X = Series trip
D = Series trip with auxiliary relay trip pole (requires extra pole package, 3 pole (4 pole package) max., must
One actuator per pole
1 = Black toggle
2 = White toggle
One actuator per unit
7 = Black toggle
Q = .250” QC (DIN 46 244) [30A Max. UL/CSA; 25A Max. VDE]
S = #8-32 screw [30A Max.]
T = #10-32 screw [50A Max.]
U = #8-32 screw, nickel plated, bent inward 30° [30A Max.]
V = #10-32 screw, nickel plated, bent inward 30° [50A Max.]
Notes: #10-32 termination must be used for all ratings of greater than 30 amps.
UL/CSA 1 = 277VAC, 50/60 Hz.
TYPES
VDE
TYPES
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve.
0.20
0.25
Blank = UL1077/CSA breaker
V = VDE approved breaker without auxiliary switch
M = UL1077/UL1500 ignition protected breaker
specify #10-32 screw terminals below, but relay trip pole will be equipped with .250” QC term. only, not UL),
relay trip pole will be on the right side of the breaker when viewed from the front.
#10-32 termination must be specified for circuit function D, but relay trip pole will be equipped with .250” QC.
See delay curve section for availability and details.
0.50
0.75
2 = 277/480VAC, 50/60 Hz. (Requires insulating barriers, see outline dimension drawing)
5 = 65VDC
7 = AC/DC 277VAC, 50/60 Hz. or 65VDC
8 = AC/DC 120VAC, 120/240VAC, 48VDC
1 = 250VAC, 415/240VAC
5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
(Time delay curve 34 must be specified.
(Time delay curve 34 must be specified.)
(Agency Approval M [UL1500] and time delay curve 34 must be specified.)
W67-X2Q12-5
W67-X2Q12-7
W67-X2Q12-10
W67-X2Q12-15
W67-X2Q12-20
W67-X2Q12-30
1.0
1.5
3 = Black rocker
4 = White rocker
8 = White toggle
68 = Two pole
Dimensions are in inches over
(millimeters) unless otherwise
specified.
2.0
2.5
10 = AC high inrush motor start / long delay
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
3.0
3.5
W67-X2Q13-1
W67-X2Q13-2
W67-X2Q13-3
W67-X2Q13-10
W67-X2Q13-15
W67-X2Q13-20
J = Black rocker
5 = Red rocker
6 = Grey rocker
4.0
5.0
69 = Three pole
)
6.0
7.0
Typical Part No.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
W67-X2Q13-25
W67-X2Q13-30
W67-X2Q50-5
W67-X2Q50-10
W67-X2Q52-5
W67-X2Q52-10
7.5
8.0
Issued 3-03 (PDF Rev. 11-08)
9 = Red toggle
Catalog 1308242
9.0
10.0
70 = Four pole
>
W67-X2Q52-15
W67-X2Q52-20
W67-X2Q52-30
W67-X2Q110-15
W67-X2Q110-20
W68-X2Q12-3
11.0
12.0
W 67- X
15.0
20.0
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
W68-X2Q12-5
W68-X2Q12-7
W68-X2Q12-10
W68-X2Q12-15
W68-X2Q12-20
W68-X2Q12-25
25.0
30.0
35.0
40.0
2
Q
45.0
50.0
W68-X2Q12-30
W68-X2Q13-15
W68-X2Q110-10
W68-X2Q110-20
W69-X2Q12-5
W69-X2Q12-10
Consult factory for
other values.
1
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080208
2- 20
W69-X2Q12-15
W69-X2Q12-20
W69-X2Q12-25
W69-X2Q12-30
W69-X2Q110-20
W69-X2Q110-30
3

Related parts for W91-A152-40