3G3AX-CUSBM002-E Omron, 3G3AX-CUSBM002-E Datasheet - Page 15

no-image

3G3AX-CUSBM002-E

Manufacturer Part Number
3G3AX-CUSBM002-E
Description
USB Cable Of G5 Drive And PC
Manufacturer
Omron
Datasheet

Specifications of 3G3AX-CUSBM002-E

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
3G3MX2
Control Circuit Terminals
Side by side mounting
Serial communication
Output
Power supply
Frequency setting
input
Sensor input
Output
Power supply
Input
Input
Enclosure
Terminal symbol
collector
Contact
Pulse
Open
Relay
Pulse
SC
FS
FV
FI
S5/TH
AM
SC
P24
PSC
S7/EB
S6
S5/TH
S4/GS2
S3/GS1
S2
S1
S4/GS2
S3/GS1
RP
S7/EB
P1/EDM
P2
P1/EDM
MA
MB
MC
MP
RS+
RS−
Terminal name
Input signal common
Frequency reference
power supply
Frequency reference input
terminal (analog voltage input)
Frequency reference
terminal (analog current input)
External thermistor input (also used
as multi-function input terminal)
Multi-function analog output
(voltage)
Input signal common
Power supply terminal for
input signal
Power supply terminal for
input terminal
Multi-function input terminal
Safety input
Pulse input-A
Pulse input-B
Multi-function output terminal
Safety monitor
Relay output terminal
Relay output common
Pulse output
Modbus port (RS-485)
Description
This is a common terminal used by the internal power supply,
digital input and analog input/output terminals.
10 VDC power supply for the FV terminal.
Use this terminal if the frequency reference is provided by
0 to 10 VDC voltage input.
Use this terminal if the frequency reference is provided by
4 to 20 mA current input.
Connect an external thermistor between the SCs, to trip the
Inverter when a temperature error occurs. (The inverter will trip
when the input from thermistor is approx. 3 kΩ or higher.) Since
this input is also used as the multifunction input terminal, setting
of C005 is required.
Specified signals can be output using voltage signals
of 0 to 10 VDC.
This is a common terminal used by the internal power
supply, digital input and analog input/output terminals.
24 VDC power supply for contact input signal.This is
used as a common terminal if the source logic is input.
Sink logic input: Shorted with P24
Source logic input: Shorted with SC
To drive the contact input using an external power supply,
remove the shorting bar.
Select 7 functions from among 59, and allocate them to terminals
S1 through S7/EB. Both sink and source logics are supported.
Enabled when the safety function selector switch is turned ON.
A pulse input for frequency setting. (Take note that the
internal circuit is different from input terminals S7/EB.)
A pulse input for frequency setting. (Take note that the
internal circuit is different from input terminal RP.)
Select 2 functions from among 43, and allocate them to terminals
P1 through P2. Both sink and source logics are supported.
Enabled when the EDM function selector switch is ON.
Select the desired functions from among 43 functions,
and allocate them to these terminals.
SPDT contact.
The factory default of Relay Output (MA, MB) Contact
Selection (C036) is NC contact between MA-MC,
and NO contact between MB-MC.
Pulses are output.
RS-485 port
RS+ RS-485 differential (+) signal
RS- RS-485 differential (−) signal
Specifications
Allowable max. current: 7 mA
Input impedance Approx. 10 kΩ
Allowable input voltage range −0.3 to +12 VDC
Input impedance 100 Ω
Allowable input range 0 to 24 mA
PTC type
AM
Allowable max. current: 100 mA
Voltage between each input and PSC
ON voltage: 18 V min.
OFF voltage: 3 V max.
Allowable max. voltage: 27 VDC
Load current: 5 mA (at 24 V)
Input pulse 32 kHz max.
Voltage between input and SC
ON voltage: 4 V min.
OFF voltage: 1 V max.
Allowable max. voltage: 27 VDC
Input pulse 1.8 kHz max.
ON voltage: 18 V min.
OFF voltage: 3 V max.
Allowable max. voltage: 27 VDC
Load current: 5 mA (at 24 V)
Open collector output
Between each terminal and PC
Allowable max. voltage: 27 V
Allowable max. current: 50 mA
Voltage drop when ON: 4 V max.
Max. contact capacity
MA-MC: 250 VAC, 2 A (resistance)
0.2 A (induction)
MB-MC: 250 VAC, 1 A (resistance)
0.2 A (induction)
Contact min. capacity
100 VAC, 10mA 5 VDC, 100 mA
Output pulse: 32 kHz max.
Output voltage: 10 VDC
Allowable max. current: 2 mA
Max. speed: 115.2 kbps
Built-in Terminal Resistor: 200 Ω
Slide switch selection