CP1HXA40DRA Omron, CP1HXA40DRA Datasheet - Page 18

no-image

CP1HXA40DRA

Manufacturer Part Number
CP1HXA40DRA
Description
40 I/O,24DI,16DO REL,4AI,2AO
Manufacturer
Omron
Datasheet

Specifications of CP1HXA40DRA

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CJ-series Special I/O Units and CPU Bus Units
CP1H CPU
Unit options
CJ-series
Special I/O
Units
CJ-series CPU
Bus Units
Category
CJ Unit Adapter
Analogue Input Units
Analogue Output Units
Analogue I/O Unit
Process Input Units
Temperature Control Units
CompoBus/S Master Unit
PROFIBUS-DP Slave Unit
Controller Link Units
Serial Communications
Units
Ethernet Unit
DeviceNet Unit
PROFIBUS-DP Master Unit Controls up to 7000 words of remote I/O data over PROFIBUS-DP CJ1W-PRM21
CAN Unit
Name
Adapter for connecting CJ-series Special I/O Units and CPU Bus
Units (includes CJ-series End Cover)
8 inputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)
Resolution: 1/8,000; Conversion speed: 250 ìs/input max.
(Can be set to 1/4,000 resolution and 1 ms/input.)
4 inputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)
Resolution: 1/8,000; Conversion speed: 250 ìs/input max.
(Can be set to 1/4,000 resolution and 1 ms/input.)
8 outputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V)
Resolution: 1/4,000; Conversion speed: 1 ms/output max.
(Can be set to 1/8000, 250 ìs/output)
8 outputs (4 to 20 mA)
Resolution: 1/4,000; Conversion speed: 1 ms/output max.
(Can be set to 1/8,000, 250 ìs/ output)
4 outputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)
Resolution: 1/4,000, Conversion speed: 1 ms/point max.
2 outputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)
Resolution: 1/4,000; Conversion speed: 1 ms/output max.
4 inputs, 2 outputs
(1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA)
Resolution: 1/4000; Conversion speed: 1 ms/point max.
(Can be set to 1/8,000, 250 ìs/point)
4 inputs, B, J, K, L, R, S, T; Conversion speed: 250 ms/4 inputs
4 inputs, Pt100 Ù (JIS, IEC), JPt100 Ù, Conversion speed: 250 ms/
4 inputs
2 inputs, B, E, J, K, L, N, R, S, T, U, W, Re5-26, PL ±100 mV,
Resolution: 1/64,000; Conversion speed: 10 ms/2 inputs
2 inputs, Pt100, JPt100, Pt50, Ni508.4;
Resolution: 1/64,000; Conversion speed: 10 ms/2 inputs
2 inputs, 0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V, 1 to 5 V, -5 to 5 V,
0 to 10 V, -10 to 10V, ±10 V selectable range, 0 to 20 mA, 4 to 20 mA
4 loops, thermocouple input, NPN output
4 loops, thermocouple input, PNP output
2 loops, thermocouple input, NPN output, heater burnout detection
function
2 loops, thermocouple input, PNP output, heater burnout detection
function
4 loops, platinum resistance thermometer input, NPN output
4 loops, platinum resistance thermometer input, PNP output
22 loops, platinum resistance thermometer input, NPN output,
heater burnout detection function
2 loops, platinum resistance thermometer input, PNP output,
heater burnout detection function
CompoBus/S remote I/O, 256 points max.
Exchanges up to 180 words in any memory area with a
PROFIBUS-DP Master Unit
Wired (Shielded twisted-pair cable)
1 RS-232C port and 1 RS-422A/485 port
2 RS-232C ports
100Base-TX
Functions as master and/or slave; allows control of 32,000 points
max. per master.
Can send and/or receive any CAN-Message
Specifications
CP1W-EXT01
CJ1W-AD081-V1
CJ1W-AD041-V1
CJ1W-DA08V
CJ1W-DA08C
CJ1W-DA041
CJ1W-DA021
CJ1W-MAD42
CJ1W-PTS51
CJ1W-PTS52
CJ1W-PTS15
CJ1W-PTS16
CJ1W-PDC15
CJ1W-TC001
CJ1W-TC002
CJ1W-TC003
CJ1W-TC004
CJ1W-TC101
CJ1W-TC102
CJ1W-TC103
CJ1W-TC104
CJ1W-SRM21
CJ1W-PRT21
CJ1W-CLK21-V1
CJ1W-SCU41-V1
CJ1W-SCU21-V1
CJ1W-ETN21
CJ1W-DRM21
CJ1W-CORT21
Model
UC1, CE, N, L
UC1, CE, N
UC1, CE, N, L
UC1, CE
UC1, CE, N, L
UC, CE
UC1, CE, N, L
UC, CE
CE
Standard
133