CPU Unit Overview and Built-in Functions
Analog Inputs Are Made Simple
An analog adjustment and an external analog setting input connector
are provided.
This connector is used for an 0 to 10-V analog input with a 256
resolution. Each CP1H/CP1L CPU Unit has one of these connectors
built in. A device, such as a potentiometer, can be connected to
enable direct manual operation and control from a control panel.
The maximum cable length is 3 meters. A connecting cable (1 m) is
included with the CPU Unit.
LCD
Data, such as programs and
initial memory values, can be
stored on a Memory Cassette
(optional) and copied to other
systems.
The Memory Cassette can also
be used when
installing new versions of
application programs.
Memory Cassette
Analog Adjustment
The analog adjustment has a
resolution of 256. Values are
entered in A642 and can be used
in the ladder program. When the
value is changed, it is displayed (0
to FF) for three seconds on the
7-segment display.
(Only CP1H CPU Units
provide a 7-segment display.)
CP1W-ME05M
Memory Cassette
The 7-segment display
provides two
display digits.
In addition to displaying
error codes for errors
detected by the PLC, codes
can be displayed on the
display from the
ladder program.
The 7-segment display is useful for maintenance as well, allowing
problems that arise during system operation to be grasped without
using any Support Software.
Battery-free Operation
Status Displayed on 7-segment Display
The values in the DM Area (32K words) are saved in the
CPU Unit’s built-in flash memory as initial values, and can be
read at startup.
Battery-free operation can be used to enable saving
production data and machine parameters in the DM
Area, turning OFF the power, and then using then same
data again for the next production run. (This is ideal for
machinery that is only used seasonally.)
Note:
A battery is required for the clock function and to retain the status of HR
Area bits and counter values.
A battery is provided as a standard feature with the CPU Unit.
The user program (ladder program) is stored in built-in flash memory, so
no battery is required to back it up.
Controlling a Fountain for a Period of Time
If bit A is ON, the fountain pump turns ON
from 10:00 AM to 7:30 PM.
Program Example A
Example display: A memory error occurs
in the UM (error code 80F1, error details 0001).
A
S1
S2
Time: 10:00 AM
C
or later.
DT
A351
D100
D0
S1
S2
C
Time: 7:30 PM
(CP1H only)
or earlier.
DT
A351
D103
D0
Fountain
100.00
pump
A351
A352
A353
D0 –
15
7