D4BL-K3 Omron, D4BL-K3 Datasheet - Page 7

Contact OSTI For Purchase

D4BL-K3

Manufacturer Part Number
D4BL-K3
Description
Contact OSTI For Purchase
Manufacturer
Omron
Type
Safety-Door Switchr
Series
D4BLr
Datasheets

Specifications of D4BL-K3

Contact Form
DPDT
Contact Rating
10 Amps
Actuator
Plunger
Operating Force
19.61 N
Termination Style
Wire
Color
Red
Mounting Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
D4BL Guard Lock Safety Door Switches
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q2025725A
D4BL
J OPERATING MODE
(Example of Electromagnetic Interlock System Operating Mode of D4BL-jCjA-A)
Note: 1. Be sure to use the dedicated push button to start or stop the machine or release the door lock.
Operating
mode
Door
Door
switch
Contact
Control
device
Machine
Indicator
2. Solenoid terminals E1and E2 of 24-VDC solenoid release models have the following polarities. Confirm the polarities before
3. Solenoid terminals E1 and E2 of 110-VAC solenoid release models have no polarity.
wiring.
E1: +
E2: --
I
The protective door is
open.
31 and 12
OFF
Orange: ON
Green:
Operation Key: The
mechanical lock is
released (contacts 31
and 32 are OFF).
Main Switch: The
normally closed contact
is forcibly opened
(contacts 11 and 12 are
OFF).
(1)
Confirmation
of door
opening
Operation Key (door)
E1
31
E1 E2 31 12 23 24
+
--
32
E2
Orange
OFF
11
23
23 and 24
ON
(2)
Safety
work
indication
12
24
Green
II
The protective door is
closed.
31 and 12
ON
Orange: OFF
Green:
Operation Key:
Mechanically locked
(contacts 31 and 32 are
ON).
Main Switch: The
normally closed contact
is closed (contacts 11
and 12 are ON).
E1
31
E1 E2 31 12 23 24
+
(Interruption)
--
32
E2
(3)
Confirmation
of door
closing
Orange
Operation Key (door)
ON
11
23
23 and 24
OFF
12
24
Green
8
III
The protective door is
closed and the machine is
operating.
31 and 12
ON
Orange: OFF
Green:
The protective door is closed
and the machine is operating.
(4)
Start
signal
(Start)
(See note)
(Processing)
E1
31
E1 E2 31 12 23 24
+
ON
--
32
(5)
Machine
interrupt
signal
E2
Orange
Operation Key (door)
11
23
23 and 24
OFF
12
24
Green
(6)
Confirmation
of machine
interruption
(Completion)
IV
The protective door is
closed and the solenoid is
operating.
31 and 12
OFF
Orange: ON
Green:
Operation Key: The
mechanical lock is
released (contacts 31
and 32 are OFF).
(7)
Lock
release
signal
E1
31
E1 E2 31 12 23 24
+
(Interruption)
--
32
Operation Key (door)
E2
Orange
ON
(8)
Release
confirmation
signal
11
23
23 and 24
OFF
Green
12
24

Related parts for D4BL-K3