EE-SX914P-R 1M Omron, EE-SX914P-R 1M Datasheet - Page 7

no-image

EE-SX914P-R 1M

Manufacturer Part Number
EE-SX914P-R 1M
Description
5mmSL PM LD PNP U SHP R CBL
Manufacturer
Omron
Datasheets

Specifications of EE-SX914P-R 1M

Sensing Method
Through-Beam
Termination Style
PCB
Output Configuration
Light-On/Dark-On
Sensing Distance
5 mm
Sensing Range
0mm To 5mm
Output Current
100mA
Sensor Output
PNP Open Collector
Supply Voltage Range Dc
5V To 24V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
EE-SX914PR1M
● Other Precautions
• Do not disconnect wire the cables from the Sensor when power is
• Do not install the Sensor in the following places to prevent
• Be sure to use the Sensor under the rated ambient temperature.
• The Sensor may be dissolved by exposure to organic solvents,
• Make sure the total length of the power cable connected to the
• Only output 2 (OUT2) on NPN models is provided with overcurrent
• An output pulse may occur when the power supply is turned ON
supplied to the Sensor, or Sensor damage could result.
malfunction or trouble:
acids, alkali, or aromatic hydrocarbons, aliphatic chloride
hydrocarbons causing deterioration in characteristics. Do not
expose the Sensor to such chemicals.
product is less than 10 m.
protection.
If an overcurrent occurs, heat generated by the output transistor will
activate the thermal shutdown circuit and OUT2 will turn OFF.
Check the wiring and load current and cycle the power supply. If
there is no overcurrent, normal operation will be resumed. (The
thermal shutdown circuit will be activated again if there is an
overcurrent.)
This function does not provide protection against load short circuits.
If the electric power of the output transistor increases due to a load
short-circuit or near load short-circuit, the Sensor may be damaged.
depending on the power supply and other conditions. The operation
of the Sensor will be stable 100 ms after turning ON the power
supply.
1. Places exposed to dust or oil mist
2. Places exposed to corrosive gas
3. Places directly or indirectly exposed to water, oil, or chemicals
4. Outdoor or places exposed to intensive light, such as direct
sunlight
EE-SX91